Literature DB >> 24492139

Is cartilage interposition required for ossiculoplasty with titanium prostheses?

Michael B Pringle1, Vishnu S Sunkaraneni, Neil Tann.   

Abstract

OBJECTIVE: To demonstrate that cartilage interposition between the head of a titanium prosthesis and the tympanic membrane is not necessary to prevent extrusion. STUDY
DESIGN: Retrospective review.
SETTING: District general hospital. PATIENTS: A retrospective review of 73 ears in patients aged between 5.9 and 64.5 years, which had an ossiculoplasty performed using a titanium prosthesis between the stapes footplate or stapes head and the tympanic membrane.
INTERVENTIONS: Use of Spiggle and Theis two part, shortenable titanium PORP and TORP and Grace Alto titanium TORP and PORP. MAIN OUTCOME MEASURES: Number of extruded prostheses. Audiometric results.
RESULTS: Five extrusions occurred in 4 patients, follow-up between 6 and 98 months. Extrusions were related to retraction of the tympanic membrane around the prosthesis. Audiometric results compared favorably with other ossiculoplasty techniques.
CONCLUSION: The titanium head of the Spiggle and Theis and Grace Alto titanium prostheses interact well with the undersurface of the tympanic membrane in patients with favorable middle ear conditions. In our experience, cartilage interposition is not mandatory.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24492139     DOI: 10.1097/MAO.0b013e31829e169b

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  3 in total

1.  Cartilage island on stapes: autologous PORP in the hypoventilated middle ear.

Authors:  Jeanette Hess-Erga; Bart Lambertus Henricus Jozef Engelen; Flemming Slinning Vassbotn
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-12-20       Impact factor: 2.503

Review 2.  Cartilage ossiculoplasty in cholesteatoma surgery: hearing results and prognostic factors.

Authors:  N Quaranta; S Taliente; F Coppola; I Salonna
Journal:  Acta Otorhinolaryngol Ital       Date:  2015-10       Impact factor: 2.124

3.  A New, Promising Experimental Ossicular Prosthesis: A Human Temporal Bone Study With Laser Doppler Vibrometry.

Authors:  Anton Rönnblom; Kilian Gladiné; Anders Niklasson; Magnus von Unge; Joris Dirckx; Krister Tano
Journal:  Otol Neurotol       Date:  2020-04       Impact factor: 2.619

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.