Literature DB >> 24491765

Development of a new green non-dispersive ionic liquid microextraction method in a narrow glass column for determination of cadmium prior to couple with graphite furnace atomic absorption spectrometry.

Tasneem Gul Kazi1, Mustafa Tuzen2, Faheem Shah1, Hassan Imran Afridi1, Demirhan Citak2.   

Abstract

Easy and innovative non-dispersive ionic liquid based microextraction (NDILME) has been developed for preconcentration of trace level of cadmium (Cd) in aqueous real surface water samples prior to couple with graphite furnace atomic absorption spectrometry (GFAAS). A 200 cm long narrow glass column containing aqueous solution of standard/sample was used to increase phase transfer ratio by providing more contact area between two medium (aqueous and extractive), which drastically improve the recoveries of labile hydrophobic chelate of Cd ammonium pyrrolidinedithiocarbamate (APDC), into ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate [C4mim][PF6]. Different aspect of the desire method have been investigated and optimized. Under the optimized key experimental variables, limit of detection (LOD) and enhancement factor (EF) were achieved to be 0.5 ng L(-1) and 150, respectively. Reliability of the model method was checked by relative standard deviation (%RSD), which was found to be <5%. Validity and accuracy of the developed method was checked by analysis of certified reference water samples (SLRS-4 Riverine water) using standard addition method. Application of the model method was productively performed by analysis of Cd in real surface water samples (tap and sea).
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Ammonium pyrrolidinedithiocarbamate; Cadmium; Graphite furnace atomic absorption spectrometry; Non dispersive ionic liquid microextraction

Mesh:

Substances:

Year:  2014        PMID: 24491765     DOI: 10.1016/j.aca.2013.12.034

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  Preconcentration and determination of lead and cadmium levels in blood samples of adolescent workers consuming smokeless tobacco products in Pakistan.

Authors:  Sadaf Sadia Arain; Tasneem Gul Kazi; Hassan Imran Afridi; Kapil Dev Brahman; Sumaira Khan; Abdul Haleem Panhwar; Muhammad Afzal Kamboh; Jamil R Memon
Journal:  Environ Monit Assess       Date:  2015-05-01       Impact factor: 2.513

2.  Trace monitoring of silver ions in food and water samples by flame atomic absorption spectrophotometry after preconcentration with solvent-assisted dispersive solid phase extraction.

Authors:  Fariborz Omidi; Mohammad Behbahani; Seyed Jamaleddin Shahtaheri; Sara Salimi
Journal:  Environ Monit Assess       Date:  2015-05-16       Impact factor: 2.513

3.  Determination of nickel in blood and serum samples of oropharyngeal cancer patients consumed smokeless tobacco products by cloud point extraction coupled with flame atomic absorption spectrometry.

Authors:  Sadaf Sadia Arain; Tasneem Gul Kazi; Jamshed Bashir Arain; Hassan Imran Afridi; Atif Gul Kazi; Syeda Nasreen; Kapil Dev Brahman
Journal:  Environ Sci Pollut Res Int       Date:  2014-06-13       Impact factor: 4.223

4.  Vortex-assisted switchable liquid-liquid microextraction for the preconcentration of cadmium in environmental samples prior to its determination with flame atomic absorption spectrometry.

Authors:  Merve Fırat; Süleyman Bodur; Büşra Tışlı; Cansu Özlü; Dotse Selali Chormey; Fatma Turak; Sezgin Bakırdere
Journal:  Environ Monit Assess       Date:  2018-06-12       Impact factor: 2.513

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.