Literature DB >> 24490188

Low velocity gunshot wounds result in significant contamination regardless of ballistic characteristics.

Joseph Weinstein, Emily Putney, Kenneth Egol1.   

Abstract

Controversy exists among the orthopedic community regarding the treatment of gunshot injuries. No consistent treatment algorithm exists for treatment of low energy gunshot wound (GSW) trauma. The purpose of this study was to critically examine the wound contamination following low velocity GSW based upon bullet caliber and clothing fiber type found within the injury track. Four types of handguns were fired at ballistic gel from a 10-foot distance. Various clothing materials were applied (denim, cotton, polyester, and wool) circumferentially around the tissue agar in a loose manor. A total of 32 specimens were examined. Each caliber handgun was fired a minimum of 5 times into a gel. Regardless of bullet caliber there was gross contamination of the entire bullet track in 100% of specimens in all scenarios and for all fiber types. Furthermore, as would be expected, the degree of contamination appeared to increase as the size of the bullet increased. Low velocity GSWs result in significant contamination regardless of bullet caliber and jacket type. Based upon our results further investigation of low velocity GSW tracks is warranted. Further clinical investigation should focus on the degree to which debridement should be undertaken.

Entities:  

Mesh:

Year:  2014        PMID: 24490188

Source DB:  PubMed          Journal:  Am J Orthop (Belle Mead NJ)        ISSN: 1078-4519


  4 in total

Review 1.  Wound ballistics 101: the mechanisms of soft tissue wounding by bullets.

Authors:  P K Stefanopoulos; D E Pinialidis; G F Hadjigeorgiou; K N Filippakis
Journal:  Eur J Trauma Emerg Surg       Date:  2015-10-15       Impact factor: 3.693

2.  [Update on gunshot wounds to extremities].

Authors:  F von Lübken; G Achatz; B Friemert; M Mauser; A Franke; E Kollig; D Bieler
Journal:  Unfallchirurg       Date:  2018-01       Impact factor: 1.000

Review 3.  The role of arthroscopy in bullet removal: A systematic review of the literature.

Authors:  Colin Cantrell; Erik Gerlach; Bennet Butler; Ujash Sheth; Vehniah Tjong
Journal:  J Orthop       Date:  2020-09-29

Review 4.  Gunshot Wound to the Hip Resulting in a Femoral Head and Acetabulum Fracture Treated With Open Reduction and Internal Fixation and Bipolar Hemiarthroplasty.

Authors:  Murphy P Martin; Matthew W Cole; Akshar H Patel; William F Sherman
Journal:  Arthroplast Today       Date:  2022-07-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.