| Literature DB >> 24485394 |
Thomas Leong1, Linda Johansson2, Pablo Juliano3, Raymond Mawson3, Sally McArthur4, Richard Manasseh2.
Abstract
The separation of milk fat from natural whole milk has been achieved by applying ultrasonic standing waves (1 MHz and/or 2 MHz) in a litre-scale (5L capacity) batch system. Various design parameters were tested such as power input level, process time, specific energy, transducer-reflector distance and the use of single and dual transducer set-ups. It was found that the efficacy of the treatment depended on the specific energy density input into the system. In this case, a plateau in fat concentration of ∼20% w/v was achieved in the creamed top layer after applying a minimum specific energy of 200 kJ/kg. In addition, the fat separation was enhanced by reducing the transducer reflector distance in the vessel, operating two transducers in a parallel set-up, or by increasing the duration of insonation, resulting in skimmed milk with a fat concentration as low as 1.7% (w/v) using raw milk after 20 min insonation. Dual mode operation with both transducers in parallel as close as 30 mm apart resulted in the fastest creaming and skimming in this study at ∼1.6 g fat/min.Keywords: Dairy processing; Milk fat globules; Natural whole milk; Raw milk; Ultrasound processing; Ultrasound separation
Mesh:
Substances:
Year: 2014 PMID: 24485394 DOI: 10.1016/j.ultsonch.2014.01.007
Source DB: PubMed Journal: Ultrason Sonochem ISSN: 1350-4177 Impact factor: 7.491