Literature DB >> 24484673

Monitoring the VEGF level in aqueous humor of patients with ophthalmologically relevant diseases via ultrahigh sensitive paper-based ELISA.

Min-Yen Hsu1, Chung-Yao Yang2, Wen-Hsin Hsu3, Keng-Hung Lin4, Chun-Yuan Wang4, Ying-Cheng Shen4, Yu-Chen Chen4, Siu-Fung Chau5, Hin-Yeung Tsai5, Chao-Min Cheng6.   

Abstract

The vascular endothelial growth factor (VEGF) level in aqueous humor has been used as an indicator to monitor specific diseases in the retinal ischemic condition. For clinical diagnosis, only about 200 μL of aqueous humor can be collected from the anterior chamber before the threat of anterior chamber collapse. It is necessary to develop an inexpensive diagnostic approach with the characteristics of highly sensitive, short operation duration, and requires small clinical sample quantities. To achieve the main objective of this study, we first prepared bevacizumab to be conjugated with HRP. We then deposited 2 μL aqueous humor from patients with different diseases onto each test zone of paper-based 96-well plates. After the colorimetric results were performed via ELISA protocol, the output signals were recorded using a commercial desktop scanner for analysis. In this study, only 2 μL from the aqueous humor of each patient was required for paper-based ELISA. The mean aqueous VEGF level was 14.4 pg/mL from thirteen patients (N = 13) with senile cataract as the control. However, the mean aqueous VEGF level from other patients with proliferative diabetic retinopathy (N = 14), age-related macular degeneration (N = 17), and retinal vein occlusion (N = 10) showed VEGF increases to 740.1 pg/mL, 383 pg/mL, and 219.4 pg/mL, respectively.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Diabetic disease; Diagnosis; Ophthalmology; Paper-based ELISA; VEGF

Mesh:

Substances:

Year:  2014        PMID: 24484673     DOI: 10.1016/j.biomaterials.2014.01.030

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  21 in total

1.  A microfluidic competitive immuno-aggregation assay for high sensitivity cell secretome detection.

Authors:  Fan Liu; Pawan Kc; Liwei Ni; Ge Zhang; Jiang Zhe
Journal:  Organogenesis       Date:  2018-06-08       Impact factor: 2.500

2.  Colored wax-printed timers for two-dimensional and three-dimensional assays on paper-based devices.

Authors:  Chen-Hsun Weng; Ming-Yi Chen; Chi-Hsiang Shen; Ruey-Jen Yang
Journal:  Biomicrofluidics       Date:  2014-11-18       Impact factor: 2.800

3.  Fabricating Cotton Analytical Devices.

Authors:  Shang-Chi Lin; Min-Yen Hsu; Chen-Meng Kuan; Fan-Gang Tseng; Chao-Min Cheng
Journal:  J Vis Exp       Date:  2016-08-30       Impact factor: 1.355

Review 4.  A review on wax printed microfluidic paper-based devices for international health.

Authors:  S Altundemir; A K Uguz; K Ulgen
Journal:  Biomicrofluidics       Date:  2017-08-30       Impact factor: 2.800

Review 5.  Changes in aqueous and vitreous inflammatory cytokine levels in proliferative diabetic retinopathy: a systematic review and meta-analysis.

Authors:  Ryan H Mason; Samuel A Minaker; Gabriela Lahaie Luna; Priya Bapat; Armin Farahvash; Anubhav Garg; Nishaant Bhambra; Rajeev H Muni
Journal:  Eye (Lond)       Date:  2022-06-07       Impact factor: 4.456

6.  Paper-based diagnostic devices for clinical paraquat poisoning diagnosis.

Authors:  Chen-Meng Kuan; Szu-Ting Lin; Tzung-Hai Yen; Yu-Lin Wang; Chao-Min Cheng
Journal:  Biomicrofluidics       Date:  2016-06-21       Impact factor: 2.800

7.  Lignocellulose-based analytical devices: bamboo as an analytical platform for chemical detection.

Authors:  Chen-Meng Kuan; Roger L York; Chao-Min Cheng
Journal:  Sci Rep       Date:  2015-12-21       Impact factor: 4.379

8.  Diagnostic values of vascular endothelial growth factor and epidermal growth factor receptor for benign and malignant hydrothorax.

Authors:  Yan Gu; Min Zhang; Guo-Hua Li; Jun-Zhen Gao; Liping Guo; Xiao-Juan Qiao; Li-Hong Wang; Lan He; Mei-Ling Wang; Li Yan; Xiu-Hua Fu
Journal:  Chin Med J (Engl)       Date:  2015-02-05       Impact factor: 2.628

9.  The Assessment of the Readiness of Molecular Biomarker-Based Mobile Health Technologies for Healthcare Applications.

Authors:  Chu Qin; Lin Tao; Yik Hui Phang; Cheng Zhang; Shang Ying Chen; Peng Zhang; Ying Tan; Yu Yang Jiang; Yu Zong Chen
Journal:  Sci Rep       Date:  2015-12-08       Impact factor: 4.379

10.  A Simple Paper-Based Colorimetric Device for Rapid Mercury(II) Assay.

Authors:  Weiwei Chen; Xueen Fang; Hua Li; Hongmei Cao; Jilie Kong
Journal:  Sci Rep       Date:  2016-08-24       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.