Literature DB >> 24484075

Compliance with remote monitoring of ICDS/CRTDS in a real-world population.

Lynda E Rosenfeld1, Amisha S Patel, Vivek B Ajmani, Reece W Holbrook, Trina A Brand.   

Abstract

BACKGROUND: Remote monitoring (RM) of defibrillators (implantable cardioverter defibrillators [ICDs]) and cardiac resynchronization therapy devices (CRTDs) has been shown to be cost effective, convenient, and associated with reduced mortality and a reduction in the time to physician intervention for actionable events. However, patient compliance with monitoring over time and what factors might influence such compliance have not been well described. This study sought to identify factors contributing to patient noncompliance with RM of ICDs and CRTDs in a large real-world population.
METHODS: Deidentified data on U.S. patients enrolled in the Medtronic CareLink RM system were used to compare patients with no (noncompliant, n = 14,848) and with ≥ 2 RM transmissions (compliant, n = 103,284) during a 14-month period.
RESULTS: Overall noncompliance with RM was 21%. Younger age (≤ 40), female sex, wanded device, Medicare Census Division, and small clinic size all predicted patient noncompliance (P < 0.01). Device type (ICD vs CRTD) did not (P = 0.52). Multivariate analysis suggested clinically important predictors of noncompliance to be: age ≤ 40, odds ratio (OR) 2.64 (95% confidence interval, 2.42-2.88); Medicare Census Division (Mountain vs West North Central), OR 2.15 (1.96-2.37); and small clinic size (1-4 vs >100 patients), OR 4.38 (3.92-4.91).
CONCLUSIONS: There is room for improvement in RM usage among enrolled patients. Younger patients, smaller clinics, and certain geographic areas may be targets for research into interventions to further improve the use of RM. ©2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  cardiac resynchronization therapy devices; implantable cardioverter defibrillators; patient compliance; remote monitoring

Mesh:

Year:  2014        PMID: 24484075     DOI: 10.1111/pace.12358

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  8 in total

1.  [Implantable cardioverter-defibrillator: Is remote monitoring obligatory?].

Authors:  Fritz W Horlbeck; J O Schwab
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-04-22

2.  Cloud Follow-Up in Patients With Cardiovascular Implantable Electronic Devices: A Single-Region Study in China.

Authors:  Lin Tong; Shiqiang Xiong; Jun Hou; Jin Li; Shujuan Qin; Yangchun Zhang; Siqi Yang; Lingyao Qi; Xu Chen; Yan Luo; Zhen Zhang; Haoyu Deng; Hanxiong Liu; Lin Cai
Journal:  Front Cardiovasc Med       Date:  2022-05-09

Review 3.  Remote monitoring of cardiac implantable electronic devices (CIED).

Authors:  Emily P Zeitler; Jonathan P Piccini
Journal:  Trends Cardiovasc Med       Date:  2016-03-31       Impact factor: 6.677

4.  Drowning in Data: Workflow Changes Improve the Collection of Clinically Relevant and Actionable Data.

Authors:  Susan Davish; Catherine Baker; Mary Fulks; Judi Godsey; Kerri Parker
Journal:  Perspect Health Inf Manag       Date:  2019-10-01

5.  How to encourage patients with implanted electronic cardiac devices to participate in remote monitoring and follow-up?

Authors:  N M van Hemel
Journal:  Neth Heart J       Date:  2014-10       Impact factor: 2.380

6.  Remote monitoring of oxygen saturation in individuals with COVID-19 pneumonia.

Authors:  Orla O'Carroll; Rachel MacCann; Aoife O'Reilly; Eleanor M Dunican; Eoin R Feeney; Silke Ryan; Aoife Cotter; Patrick W Mallon; Michael P Keane; Marcus W Butler; Cormac McCarthy
Journal:  Eur Respir J       Date:  2020-08-13       Impact factor: 16.671

Review 7.  Impact of COVID-19 Pandemic on Cardiac Electronic Device Management and Role of Remote Monitoring.

Authors:  Michele Magnocavallo; Giampaolo Vetta; Alessia Bernardini; Agostino Piro; Maria Chiara Mei; Martina Di Iorio; Marco Valerio Mariani; Domenico G Della Rocca; Paolo Severino; Raffaele Quaglione; Giuseppe Giunta; Cristina Chimenti; Fabio Miraldi; Carmine Dario Vizza; Francesco Fedele; Carlo Lavalle
Journal:  Card Electrophysiol Clin       Date:  2021-10-30

8.  Performance of first pacemaker to use smart device app for remote monitoring.

Authors:  Khaldoun G Tarakji; Amir M Zaidi; Steven L Zweibel; Niraj Varma; Samuel F Sears; James Allred; Paul R Roberts; Naushad A Shaik; Josh R Silverstein; Abdul Maher; Suneet Mittal; Ashish Patwala; John Schoenhard; Martin Emert; Giulio Molon; Giuseppe Augello; Nilam Patel; Hanscy Seide; Antonio Porfilio; Baerbel Maus; Sherry L Di Jorio; Keith Holloman; Ana C Natera; Mintu P Turakhia
Journal:  Heart Rhythm O2       Date:  2021-08-02
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.