Fast Switching of CO3(-)(H2O)n and O2(-)(H2O)n reactant ions in dopant-assisted negative photoionization ion mobility spectrometry for explosives detection.

Shasha Cheng1, Weiguo Wang, Qinghua Zhou, Chuang Chen, Liying Peng, Lei Hua, Yang Li, Keyong Hou, Haiyang Li.   

Abstract

Ion mobility spectrometry (IMS) has become the most deployed technique for on-site detection of trace explosives, and the reactant ions generated in the ionization source are tightly related to the performances of IMS. Combination of multiform reactant ions would provide more information and is in favor of correct identification of explosives. Fast switchable CO3(-)(H2O)n and O2(-)(H2O)n reactant ions were realized in a dopant-assisted negative photoionization ion mobility spectrometer (DANP-IMS). The switching could be achieved in less than 2 s by simply changing the gas flow direction. Up to 88% of the total reactant ions were CO3(-)(H2O)n in the bidirectional mode, and 89% of that were O2(-)(H2O)n in the unidirectional mode. The characteristics of combination of CO3(-)(H2O)n and O2(-)(H2O)n were demonstrated by the detection of explosives, including 2,4,6-trinitrotoluene (TNT), cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX), ammonium nitrate fuel oil (ANFO), and black powder (BP). For TNT, RDX, and BP, product ions with different reduced mobility values (K0) were observed with CO3(-)(H2O)n and O2(-)(H2O)n, respectively, which is a benefit for the accurate identification. For ANFO, the same product ions with K0 of 2.07 cm(2) V(-1) s(-1) were generated, but improved peak-to-peak resolution as well as sensitivity were achieved with CO3(-)(H2O)n. Moreover, an improved peak-to-peak resolution was also obtained for BP with CO3(-)(H2O)n, while the better sensitivity was obtained with O2(-)(H2O)n.

Entities:  

Year:  2014        PMID: 24484058     DOI: 10.1021/ac404067z

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Ultra-High Resolution Ion Mobility Separations Utilizing Traveling Waves in a 13 m Serpentine Path Length Structures for Lossless Ion Manipulations Module.

Authors:  Liulin Deng; Yehia M Ibrahim; Ahmed M Hamid; Sandilya V B Garimella; Ian K Webb; Xueyun Zheng; Spencer A Prost; Jeremy A Sandoval; Randolph V Norheim; Gordon A Anderson; Aleksey V Tolmachev; Erin S Baker; Richard D Smith
Journal:  Anal Chem       Date:  2016-08-26       Impact factor: 6.986

2.  Detection of nitro-based and peroxide-based explosives by fast polarity-switchable ion mobility spectrometer with ion focusing in vicinity of Faraday detector.

Authors:  Qinghua Zhou; Liying Peng; Dandan Jiang; Xin Wang; Haiyan Wang; Haiyang Li
Journal:  Sci Rep       Date:  2015-05-29       Impact factor: 4.379

3.  On-site rapid detection of trace non-volatile inorganic explosives by stand-alone ion mobility spectrometry via acid-enhanced evaporization.

Authors:  Liying Peng; Lei Hua; Weiguo Wang; Qinghua Zhou; Haiyang Li
Journal:  Sci Rep       Date:  2014-10-16       Impact factor: 4.379

4.  Improved analytical performance of photoionization ion mobility spectrometry for the rapid detection of organophosphorus pesticides using K 0 patterns with multiple reactant ions.

Authors:  Qinghua Zhou; Bin Wang; Jia Li; Zanhui Jin; Haiyang Li; Jinyuan Chen
Journal:  RSC Adv       Date:  2018-05-16       Impact factor: 3.361

5.  Miniaturized Photo-Ionization Fourier Deconvolution Ion Mobility Spectrometer for the Detection of Volatile Organic Compounds.

Authors:  Binwang Yang; Jianna Yu; Wen Liu; Guoxing Jing; Wenshan Li; Wenjie Liu
Journal:  Sensors (Basel)       Date:  2022-07-22       Impact factor: 3.847

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.