Literature DB >> 24480527

Clinically relevant quality assurance (QA) for prostate RapidArc plans: gamma maps and DVH-based evaluation.

M Cozzolino1, C Oliviero2, G Califano2, S Clemente2, P Pedicini2, R Caivano2, C Chiumento2, A Fiorentino2, V Fusco2.   

Abstract

The aim of this paper is to evaluate clinically relevant quality assurance (QA) tests for RapidArc prostate patients. 26 plans were verified by the COMPASS system that provides an independent angle response and a reconstruction of dose distribution in patient CT model. Plan data were imported from treatment planning system via DICOM. The fluencies, measured by a 2D detector, were used by COMPASS to forward calculate dose in CT patients and reconstruct dose-volume-histogram (DVH). The gamma analysis was performed, using both the criteria 3%-3-mm and 2%-2 mm, for the whole grid patient and the per-structure volume. A DVH-based analysis was accomplished for target and organs-at-risk (OAR). The correlation between gamma passing rates and DVH discrepancies was performed using Pearson's test. Sensitivity, specificity and accuracy of whole and per-structure gamma method were calculated. No significant DVH deviation was observed for target and OAR. Weak correlation between gamma passing rates and dosimetric deviations was observed, all significant r-values were negative. The whole gamma method shows lack of sensitivity to detect dosimetric deviations >5%. Instead, a better balance between sensitivity and specificity was obtained employing per structure gamma both with 3%-3 mm and 2%-2 mm criteria. Because of the poor correlation between DVH goals and gamma passing rates, we encourage the DVH-based gamma passing rates, when it is possible. At least, a gamma method specific for structure was strongly suggested.
Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  3D gamma; 3D quality assurance; COMPASS system; RapidArc prostate

Mesh:

Year:  2014        PMID: 24480527     DOI: 10.1016/j.ejmp.2014.01.003

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  8 in total

1.  Optimizing the Region for Evaluation of Global Gamma Analysis for Nasopharyngeal Cancer (NPC) Pretreatment IMRT QA by COMPASS: A Retrospective Study.

Authors:  Wenli Lu; Ying Li; Wei Huang; Haixia Cui; Hanyin Zhang; Xin Yi
Journal:  Front Oncol       Date:  2022-06-14       Impact factor: 5.738

2.  Experimental verification of a 3D in vivo dose monitoring system based on EPID.

Authors:  Xiaoyong Wang; Lixin Chen; Conghua Xie; Dajiang Wang; Gaili Chen; Zhengming Fu; Hui Liu
Journal:  Oncotarget       Date:  2017-11-30

3.  A comprehensive and clinical-oriented evaluation criteria based on DVH information and gamma passing rates analysis for IMRT plan 3D verification.

Authors:  Xin Yi; Wen-Li Lu; Jun Dang; Wei Huang; Hai-Xia Cui; Wan-Chun Wu; Ying Li; Qing-Feng Jiang
Journal:  J Appl Clin Med Phys       Date:  2020-05-20       Impact factor: 2.102

4.  Pre-treatment 2D and 3D dosimetric verification of volumetric arc therapy. A correlation study between gamma index passing rate and clinical dose volume histogram.

Authors:  Lukasz Szczurek; Robert Juszkat; Jolanta Szczurek; Ilona Turek; Piotr Sosnowski
Journal:  PLoS One       Date:  2019-08-13       Impact factor: 3.240

5.  Validation of a method for in vivo 3D dose reconstruction in SBRT using a new transmission detector.

Authors:  Yuji Nakaguchi; Takeshi Ono; Masato Maruyama; Yoshinobu Shimohigashi; Yudai Kai
Journal:  J Appl Clin Med Phys       Date:  2017-06-02       Impact factor: 2.102

6.  Retrospective dosimetry study of intensity-modulated radiation therapy for nasopharyngeal carcinoma: measurement-guided dose reconstruction and analysis.

Authors:  Wen-Zhao Sun; Dan-Dan Zhang; Ying-Lin Peng; Li Chen; De-Hua Kang; Bin Wang; Xiao-Wu Deng
Journal:  Radiat Oncol       Date:  2018-03-15       Impact factor: 3.481

7.  Practical implications for the quality assurance of modulated radiation therapy techniques using point detector arrays.

Authors:  Steffi Kantz; Almut Troeller McDermott; Matthias Söhn; Sabine Reinhardt; Claus Belka; Katia Parodi; Michael Reiner
Journal:  J Appl Clin Med Phys       Date:  2017-08-30       Impact factor: 2.102

8.  Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer.

Authors:  Yuri Jeong; Jeong Geun Oh; Jeong Ku Kang; Sun Rock Moon; Kang Kyoo Lee
Journal:  Radiat Oncol J       Date:  2020-03-25
  8 in total