Detection of diminished response to cold pressor test in smokers: assessment using phase-contrast cine magnetic resonance imaging of the coronary sinus.

Shingo Kato1, Kakuya Kitagawa2, Yeonyee E Yoon1, Hiroshi Nakajima3, Motonori Nagata1, Shinichi Takase1, Shiro Nakamori3, Masaaki Ito3, Hajime Sakuma1.   

Abstract

PURPOSE: The purposes of this study were to evaluate the reproducibility for measuring the cold pressor test (CPT)-induced myocardial blood flow (MBF) alteration using phase-contrast (PC) cine MRI, and to determine if this approach could detect altered MBF response to CPT in smokers.
MATERIALS AND METHODS: After obtaining informed consent, ten healthy male non-smokers (mean age: 28±5 years) and ten age-matched male smokers (smoking duration ≥5 years, mean age: 28±3 years) were examined in this institutional review board approved study. Breath-hold PC cine MR images of the coronary sinus were obtained with a 3T MR imager with 32 channel coils at rest and during a CPT performed after immersing one foot in ice water. MBF was calculated as coronary sinus flow divided by the left ventricular (LV) mass which was given as a total LV myocardial volume measured on cine MRI multiplied by the specific gravity (1.05 g/mL).
RESULTS: In non-smokers, MBF was 0.86±0.25 mL/min/g at rest, with a significant increase to 1.20±0.36 mL/min/g seen during CPT (percentage change of MBF (∆MBF (%)); 39.2%±14.4%, p<0.001). Inter-study reproducibility for ∆MBF (%) measurements by different MR technologist was good, as indicated by the intraclass correlation coefficient of 0.93 and reproducibility coefficient of 10.5%. There was no significant difference between smokers and non-smokers for resting MBF (0.85±0.32 mL/min/g, p=0.91). However, ∆MBF (%) in smokers was significantly reduced (-4.0±32.2% vs. 39.2±14.4%, p=0.011).
CONCLUSION: PC cine MRI can be used to reproducibly quantify MBF response to CPT and to detect impaired flow response in smokers. This MR approach may be useful for monitoring the sequential change of coronary blood flow in various potentially pathologic conditions and for investigating its relationship with cardiovascular risk.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3T MR imager; Cold Pressor Test; Coronary endothelial function; Nitric oxide; Phase-Contrast Cine Magnetic Resonance Imaging; Smoker

Mesh:

Year:  2013        PMID: 24480156     DOI: 10.1016/j.mri.2013.12.015

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  2 in total

1.  Effect of short-term smoking & L-arginine on coronary endothelial function assessed by cardiac magnetic resonance cold pressor testing: a pilot study.

Authors:  Andreas M Weng; Herbert Köstler; Thorsten A Bley; Christian O Ritter
Journal:  BMC Cardiovasc Disord       Date:  2021-05-12       Impact factor: 2.298

2.  Incremental prognostic value of coronary flow reserve determined by phase-contrast cine cardiovascular magnetic resonance of the coronary sinus in patients with diabetes mellitus.

Authors:  Shingo Kato; Kazuki Fukui; Sho Kodama; Mai Azuma; Tae Iwasawa; Kazuo Kimura; Kouichi Tamura; Daisuke Utsunomiya
Journal:  J Cardiovasc Magn Reson       Date:  2020-10-08       Impact factor: 5.364

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.