Long-term evaluation of analytical methods used in sirolimus therapeutic drug monitoring.

David W Holt1, Didier A Mandelbrot, Michael A Tortorici, Joan M Korth-Bradley, Debra Sierka, Daniel I Levy, Sandi See Tai, Gary L Horowitz.   

Abstract

Results of therapeutic monitoring of sirolimus blood concentrations are assay and laboratory dependent. This study compared performance over time of the IMx microparticle enzyme immunoassay (MEIA), Architect chemiluminescent microparticle immunoassay (CMIA), and liquid chromatography with mass spectrometric detection (LC/MS/MS) as part of a proficiency testing scheme. Pooled samples from sirolimus-treated patients and whole-blood samples spiked with known quantities of sirolimus were assayed monthly between 2004 and 2012. When results of pooled patient samples were compared with LC/MS/MS, the MEIA assay showed an overall mean percent bias of -2.3% ± 11.2% that, although initially positive, became increasingly negative from 2007 through 2009. The CMIA, which replaced the MEIA assay, had a mean percent bias of 21.9% ± 12.3%, remaining stable from 2007 through 2012. Similarly, for spiked samples, the MEIA showed an increasingly negative bias over time vs. LC/MS/MS, whereas CMIA maintained a stable positive bias. Based on comparison of immunoassay measurements on individual patient samples, CMIA values were more than 25% higher than MEIA values. These results highlight the importance of continued proficiency testing and regular monitoring of sirolimus assay performance. Clinicians must be aware of the methodology used and adjust target levels accordingly to avoid potential effects on efficacy and toxicity.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  assay calibration; immunoassay; liquid chromatography; sirolimus; therapeutic drug monitoring

Mesh:

Substances:

Year:  2014        PMID: 24476346     DOI: 10.1111/ctr.12305

Source DB:  PubMed          Journal:  Clin Transplant        ISSN: 0902-0063            Impact factor:   2.863


  2 in total

Review 1.  Emerging applications of metabolomics in drug discovery and precision medicine.

Authors:  David S Wishart
Journal:  Nat Rev Drug Discov       Date:  2016-03-11       Impact factor: 84.694

2.  Multi-center Performance Evaluations of Tacrolimus and Cyclosporine Electrochemiluminescence Immunoassays in the Asia-Pacific Region.

Authors:  Xuzhen Qin; Jianzhong Rui; Yong Xia; Hong Mu; Sang Hoon Song; Raja Elina Raja Aziddin; Gabrielle Miles; Yuli Sun; Sail Chun
Journal:  Ann Lab Med       Date:  2018-03       Impact factor: 3.464

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.