Literature DB >> 24475498

Validation of noninvasive pulse contour cardiac output using finger arterial pressure in cardiac surgery patients requiring fluid therapy.

Charlotte Hofhuizen, Benno Lansdorp, Johannes G van der Hoeven, Gert-Jan Scheffer, Joris Lemson.   

Abstract

INTRODUCTION: Nexfin (Edwards Lifesciences, Irvine, CA) allows for noninvasive continuous monitoring of blood pressure (ABPNI) and cardiac output (CONI) by measuring finger arterial pressure (FAP). To evaluate the accuracy of FAP in measuring ABPNI and CONI as well as the adequacy of detecting changes in ABP and CO, we compared FAP to intra-arterially measured blood pressure (ABPIA) and transpulmonary thermodilution(COTD) in post cardiac surgery patients during a fluid challenge (FC).
METHODS: Twenty sedated patients post cardiac surgery were included, and 28 FCs were performed. Measurements of ABP and CO were simultaneously collected before and after an FC, and we compared CO and blood pressure.
RESULTS: Finger arterial pressure was obtainable in all patients.When comparing ABPNI with ABPIA, bias was2.7 mm Hg (limits of agreement [LOA], ± 22.2), 4.9 mm Hg (LOA, ± 13.6), and 4.2 mm Hg (LOA, ±13.7) for systolic,diastolic, and mean arterial pressure, respectively. Concordance between changes in ABPNI and ABPIA was 100%.Mean bias between CONI and COTD was -0.26 (LOA, ± 2.2), with a percentage error of 38.9%. Concordance between changes in CONI vs COTD and was 100%.
CONCLUSION: Finger arterial pressure reliably measures ABP and adequately tracks changes in ABP. Although CONI is not interchangeable with COTD, it follows changes in CO closely.

Entities:  

Mesh:

Year:  2014        PMID: 24475498     DOI: 10.1016/j.jcrc.2013.09.005

Source DB:  PubMed          Journal:  J Crit Care        ISSN: 0883-9441            Impact factor:   3.425


  10 in total

Review 1.  [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

Authors:  G Pestel; K Fukui; M Higashi; I Schmidtmann; C Werner
Journal:  Anaesthesist       Date:  2018-06       Impact factor: 1.041

Review 2.  Pulse waveform hemodynamic monitoring devices: recent advances and the place in goal-directed therapy in cardiac surgical patients.

Authors:  Adham Hendy; Şerban Bubenek
Journal:  Rom J Anaesth Intensive Care       Date:  2016-04

3.  The Feasibility of a Novel Index From a Wireless Doppler Ultrasound Patch to Detect Decreasing Cardiac Output in Healthy Volunteers.

Authors:  Jon-Émile S Kenny; Andrew M Eibl; Matthew Parrotta; Bradley F Long; Joseph K Eibl
Journal:  Mil Med       Date:  2021-01-25       Impact factor: 1.437

4.  A wearable carotid Doppler tracks changes in the descending aorta and stroke volume induced by end-inspiratory and end-expiratory occlusion: A pilot study.

Authors:  Jon-Émile S Kenny; Igor Barjaktarevic; Andrew M Eibl; Matthew Parrotta; Bradley F Long; Joseph K Eibl
Journal:  Health Sci Rep       Date:  2020-10-05

5.  Continuous noninvasive cardiac output determination using the CNAP system: evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour.

Authors:  Julia Y Wagner; Julian Grond; Jürgen Fortin; Ileana Negulescu; Miriam Schöfthaler; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2015-07-31       Impact factor: 2.502

6.  Pulse-contour derived cardiac output measurements in morbid obesity: influence of actual, ideal and adjusted bodyweight.

Authors:  Chantal A Boly; Pieter Schraverus; Floris van Raalten; Jan-Willem Coumou; Christa Boer; Simone van Kralingen
Journal:  J Clin Monit Comput       Date:  2017-08-18       Impact factor: 2.502

7.  A Carotid Doppler Patch Accurately Tracks Stroke Volume Changes During a Preload-Modifying Maneuver in Healthy Volunteers.

Authors:  Jon-Émile S Kenny; Igor Barjaktarevic; Andrew M Eibl; Matthew Parrotta; Bradley F Long; Joseph K Eibl; Frederic Michard
Journal:  Crit Care Explor       Date:  2020-01-29

8.  Accuracy of noninvasive continuous arterial pressure monitoring using ClearSight during one-lung ventilation.

Authors:  Sang-Wook Lee; Sangho Lee; Hyungtae Kim; Yun-Jong Kim; Mihyeon Kim; Jeong-Hyun Choi
Journal:  Medicine (Baltimore)       Date:  2021-03-19       Impact factor: 1.817

9.  Non-invasive continuous blood pressure monitoring using the ClearSight system for pregnant women at high risks of post-partum hemorrhage: comparison with invasive blood pressure monitoring during cesarean section.

Authors:  Takuya Misugi; Takashi Juri; Koichi Suehiro; Kohei Kitada; Yasushi Kurihara; Mie Tahara; Akihiro Hamuro; Akemi Nakano; Masayasu Koyama; Takasi Mori; Daisuke Tachibana
Journal:  Obstet Gynecol Sci       Date:  2022-06-27

Review 10.  Improving Perioperative Outcomes Through Minimally Invasive and Non-invasive Hemodynamic Monitoring Techniques.

Authors:  Takashige Yamada; Susana Vacas; Yann Gricourt; Maxime Cannesson
Journal:  Front Med (Lausanne)       Date:  2018-05-17
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.