Literature DB >> 24469540

A paper disk equipped with graphene/polyaniline/Au nanoparticles/glucose oxidase biocomposite modified screen-printed electrode: toward whole blood glucose determination.

Fen-Ying Kong1, Sai-Xi Gu2, Wei-Wei Li1, Ting-Ting Chen1, Qin Xu3, Wei Wang4.   

Abstract

In this work, a convenient, fast, low cost, small sample volume and in situ detection of glucose in human whole blood has been developed by using a disposable screen-printed carbon electrode (SPCE) coupled with a paper disk. To perform the assay, the SPCE was modified with graphene/polyaniline/Au nanoparticles/glucose oxidase (Gr/PANI/AuNPs/GOD) biocomposite and then covered by a paper disk impregnated with the sample. After introducing PBS on the paper disk, the electrochemical measurement was carried out. The assay was based on measuring the current decrease of flavin adenine dinucleotide (FAD) in GOD provoked by the enzyme-substrate reaction using differential pulse voltammetry (DPV). The analytical performance was comparable to conventional methods, and covered the full range of clinically relevant concentrations of glucose in whole blood. This new paper-based electrochemical glucose sensor shows promise in applying point-of-care (POC) device in whole blood tests, and particularly being appropriate for use in the developing world and in resource-limited settings.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electrochemical detection; Glucose; Paper disk; Screen-printed carbon electrodes; Whole blood

Mesh:

Substances:

Year:  2014        PMID: 24469540     DOI: 10.1016/j.bios.2013.12.067

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  21 in total

Review 1.  Gold Nanoparticles for In Vitro Diagnostics.

Authors:  Wen Zhou; Xia Gao; Dingbin Liu; Xiaoyuan Chen
Journal:  Chem Rev       Date:  2015-06-26       Impact factor: 60.622

2.  Paper-based analytical devices for point-of-care blood tests.

Authors:  Hao Yuan; Ping-Yeh Chiu; Chien-Fu Chen
Journal:  Biomicrofluidics       Date:  2021-07-23       Impact factor: 2.800

Review 3.  Paper-based analytical devices for clinical diagnosis: recent advances in the fabrication techniques and sensing mechanisms.

Authors:  Mazhar Sher; Rachel Zhuang; Utkan Demirci; Waseem Asghar
Journal:  Expert Rev Mol Diagn       Date:  2017-04       Impact factor: 5.225

Review 4.  Enzyme Immobilization on Gold Nanoparticles for Electrochemical Glucose Biosensors.

Authors:  Wiktoria Lipińska; Katarzyna Grochowska; Katarzyna Siuzdak
Journal:  Nanomaterials (Basel)       Date:  2021-04-28       Impact factor: 5.076

5.  Direct electrochemical measurement of metanephrines in spot urine samples for the diagnosis of phaeochromocytomas.

Authors:  Zheng-Hu Shi; Xiao-Qing Zhang; Qian-Na Zhen; Ming Zuo; Gang Tian; Yi-Fan He; Min Ding
Journal:  Sci Rep       Date:  2017-08-14       Impact factor: 4.379

6.  Analytical Parameters of an Amperometric Glucose Biosensor for Fast Analysis in Food Samples.

Authors:  Margalida Artigues; Jordi Abellà; Sergi Colominas
Journal:  Sensors (Basel)       Date:  2017-11-14       Impact factor: 3.576

7.  Electrochemical Hydroxylation of C3-C12 n-Alkanes by Recombinant Alkane Hydroxylase (AlkB) and Rubredoxin-2 (AlkG) from Pseudomonas putida GPo1.

Authors:  Yi-Fang Tsai; Wen-I Luo; Jen-Lin Chang; Chun-Wei Chang; Huai-Chun Chuang; Ravirala Ramu; Guor-Tzo Wei; Jyh-Myng Zen; Steve S-F Yu
Journal:  Sci Rep       Date:  2017-08-21       Impact factor: 4.379

8.  An Enzymatic Glucose Sensor Composed of Carbon-Coated Nano Tin Sulfide.

Authors:  Ren-Jei Chung; An-Ni Wang; Shiuan-Ying Peng
Journal:  Nanomaterials (Basel)       Date:  2017-02-15       Impact factor: 5.076

9.  Graphene as a signal amplifier for preparation of ultrasensitive electrochemical biosensors.

Authors:  Jaroslav Filip; Peter Kasák; Jan Tkac
Journal:  Chem Zvesti       Date:  2014-11-28       Impact factor: 2.097

Review 10.  Biosensing with Paper-Based Miniaturized Printed Electrodes-A Modern Trend.

Authors:  Célia M Silveira; Tiago Monteiro; Maria Gabriela Almeida
Journal:  Biosensors (Basel)       Date:  2016-09-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.