Literature DB >> 24468351

Improvements on bar adsorptive microextraction (BAμE) technique--application for the determination of insecticide repellents in environmental water matrices.

C Almeida1, Rafał Strzelczyk1, J M F Nogueira2.   

Abstract

Bar adsorptive microextraction combined with micro-liquid desorption followed by large volume injection-gas chromatography-mass spectrometry operating in the selected-ion monitoring acquisition mode (BAµE-µLD/LVI-GC-MS(SIM)), is proposed for the determination of trace levels of three insecticide repellents (N,N-diethyl-meta-toluamide (DEET), cis and trans permethrin (PERM)) in environmental water matrices. By comparing different sorbent coatings (five activated carbons and six polymers) through BAµE, an activated carbon (AC2) proved to be the best compromise between selectivity and efficiency, even against polydimethylsiloxane through stir bar sorptive extraction. The novel improvement proposed on the back-extraction stage performed in a single step, by reducing the desorption solvent volume at the microliter level, demonstrated remarkable performance turning possible to save time, making easier the practical manipulation and more environmentally friendly. Assays performed by BAµE(AC2)-µLD/LVI-GC-MS(SIM) on 25 mL of ultrapure water samples spiked at the 1.0 μg/L level, yielded recoveries ranging from 73.8±8.8% (trans-PERM) to 96.4±9.9% (DEET), under optimised experimental conditions. The analytical performance showed convenient detection limits (8-20 ng/L) and good linear dynamic ranges (0.04-4.0 µg/L) with suitable determination coefficients (r(2)>0.9963, DEET). Excellent repeatability were also achieved through intraday (RSD<14.9%) and interday (RSD<11.9%) experiments. The novel improvement on downsizing the BAµE device to half-size proved to be either a promising option in forthcoming to reduce still more the desorption solvent volume without losing microextraction efficiency. By using the standard addition methodology, the application of the present analytical approach on tap, ground, river, swimming-pool and estuary water samples revealed good sensitivity at trace level and absence of matrix effects.
© 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  BAµE-µLD; DEET; Environmental water matrices; Floating sampling technology; Insecticide repellents; LVI-GC–MS(SIM); Nanostructured materials; Sorbent phases; Trace analysis; cis and trans PERM

Mesh:

Substances:

Year:  2013        PMID: 24468351     DOI: 10.1016/j.talanta.2013.11.031

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Bar Adsorptive Microextraction Coated with Carbon-based Phase Mixtures for Performance-Enhancement to Monitor Selected Benzotriazoles, Benzothiazoles, and Benzenesulfonamides in Environmental Water Matrices.

Authors:  Samir M Ahmad; Bruno B C Calado; Mariana N Oliveira; Nuno R Neng; J M F Nogueira
Journal:  Molecules       Date:  2020-05-02       Impact factor: 4.411

2.  Application of Bar Adsorptive Microextraction for the Determination of Levels of Tricyclic Antidepressants in Urine Samples.

Authors:  Mariana N Oliveira; Oriana C Gonçalves; Samir M Ahmad; Jaderson K Schneider; Laiza C Krause; Nuno R Neng; Elina B Caramão; José M F Nogueira
Journal:  Molecules       Date:  2021-05-22       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.