Literature DB >> 24468347

Headspace solid-phase microextraction coupled to gas chromatography for the analysis of aldehydes in edible oils.

Chunhua Ma1, Jiaojiao Ji2, Connieal Tan2, Dongmei Chen3, Feng Luo3, Yiru Wang2, Xi Chen4.   

Abstract

Oxidation has important effects on the quality of edible oils. In particular, the generation of aldehydes produced by the oxidation of oils is one of the deteriorative factors to their quality. The aim of this study was to develop a method to determine the aldehydes as lipid oxidation markers in edible oils. Seven aldehydes generated from lipid oxidation were studied using headspace solid-phase microextraction coupled to gas chromatography with a flame ionization detector. The extraction efficiency of five commercial fibers was investigated and the influence of extraction temperature, extraction time, desorption temperature, and desorption time were optimized. The best result was obtained with 85 μm carboxen/polydimethylsiloxane, extraction at 50 °C for 15 min and desorption in the gas chromatography injector at 250 °C for 2 min. Under the optimized conditions, the content of hexanal was the highest of the seven aldehydes in all edible oils. The limits of detection for hexanal in the three oils were found to range from 4.6 to 10.2 ng L(-1). The reproducibility of the method was evaluated and the relative standard deviations were less than 8.9%. This developed approach was successfully applied to analyze hexanal in peanut oil, soy oil, and olive oil samples, and these results were compared with those obtained using the thiobarbituric acid-reactive substances (TBARs) method.
© 2013 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aldehydes; Edible oils; Headspace solid phase microextraction; Hexanal; Lipid oxidation

Mesh:

Substances:

Year:  2013        PMID: 24468347     DOI: 10.1016/j.talanta.2013.11.021

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Analysis of formaldehyde and acrolein in the aqueous samples using a novel needle trap device containing nanoporous silica aerogel sorbent.

Authors:  Abdullah Barkhordari; Mansour R Azari; Rezvan Zendehdel; Mahmoud Heidari
Journal:  Environ Monit Assess       Date:  2017-03-20       Impact factor: 2.513

2.  Trace carbonyl analysis in water samples by integrating magnetic molecular imprinting and capillary electrophoresis.

Authors:  Jiahua He; Jiawei Liu; Yangyang Liu; Zhengxi Liyin; Xiaoyi Wu; Gang Song; Yeyang Hou; Ruixi Wang; Wenfeng Zhao; Hui Sun
Journal:  RSC Adv       Date:  2021-10-06       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.