Mehdi Jahangiri, Javad Adl1, Seyed Jamaleddin Shahtaheri, Hossein Kakooe, Abbas Rahimi Forushani, Mohammad Reza Ganjali.
Abstract
In the absence of End of Service Life Indicator (ESLI), a cartridge change schedule should be established for ensuring that cartridges are changed before their end of service life. Factors effecting service life of cartridges were evaluated, including the amount of atmospheric contamination with aromatic hydrocarbon vapors in the workplace, temperature, and relative humidity of the air. A new change schedule was established based on comparing the results of air monitoring and workplace conditions, laboratory experiment, and the NIOSH MultiVapor software. Spray painters were being exposed to aromatic hydrocarbons in a range exceeding occupational exposure limits. The cartridge change schedule was not effective and could no longer provide adequate protection against organic contaminants for sprayers. Change schedules for respirator cartridges should be reduced from 16-24 hours to 4 hours. NIOSH's service life software program could be applied to developing cartridge change schedules.Entities:
Year: 2014 PMID: 24468234 PMCID: PMC3928618 DOI: 10.1186/2052-336X-12-41
Source DB: PubMed Journal: J Environ Health Sci Eng
Figure 1Schematic diagram of the set-up for field testing of cartridge change-out schedule.
Figure 2A schematic diagram of the apparatus used for measuring the cartridge breakthrough time.
Workplace air monitoring and other characteristics of workplace
| Concentration (ppm) | Benzene | 24 | 36.22 ± 21.22 | 0.5 | 36.05 | 5.09 | 0.001 | 58 |
| Toluene | 111.33 ± 61.79 | 20 | 91.44 | 4.42 | 0.002 | 174 | ||
| Xylenes | 312.33 ± 91.33 | 100 | 212.92 | 6.99 | 0.000 | 404 | ||
| Temperature (C) | 6 | 20.83 ± 0.68 | - | - | - | - | 22 | |
| Relative humidity (%) | 6 | 54.5 ± 0.5 | - | - | - | - | 55 | |
M ± SD; Mean ± Standard Deviation, MD; mean Difference, TLV; Threshold Limit Value ACGIH (8-hour TWA).
*One-sample Test.
**Worst case conditions were calculated by adding mean measured values to their standard deviation.
Estimation of cartridge service life by experiment, manufacturer's calculation and NIOSH MultiVapor software
| Single vapors | Benzene | 58 | 0.25 | 1355.3 | 1487 | 9.71 |
| Toluene | 174 | 10 | 877.2 | 958.7 | 9.29 | |
| Xylenes* | 404 | 50 | 514.4 | 9.32 | 10.28 | |
| Mixtures | Benzene, Toluene and Xylenes | 0.25 | 261.3 | 294.3 | 12.62 | |
*Estimation for xylenes has been done based on the primary component of m-xylene, Atmospheric Pressure (atm): 1.