Literature DB >> 24467440

"Rolling" phenomenon in twin screw granulation with controlled-release excipients.

M R Thompson1, K P O'Donnell.   

Abstract

The developed knowledge regarding use of twin screw granulators for continuous wet granulation has been primarily limited to immediate release formulations in the literature. The present study highlights an issue previously unreported for wet granulation with twin screw extruders when using formulations containing controlled-release (CR) excipients. Long (3-10 mm), twisted noodle-like granules can be produced in the presence of these excipients that are difficult to control and are anticipated to create complications in downstream unit operations to the granulator. Working with two different CR excipients, METHOCEL™ K4M and Kollidon® SR, each blended at different ratios with a mixture of 80% α-lactose monohydrate/20% microcrystalline cellulose, these unique particles were found to be produced in the conveying elements of the extruder, arising from a rolling action at the top of the screw flights. The CR excipients adhesively strengthen the wetted mass, forming this undesired granule shape such that they persisted to the exit of the machine; the shape appeared most strongly affected by screw speed, producing particles of higher aspect ratio as speed was increased. Adjusting the concentration of these CR excipients in the formulation, the flow rate or the type of compression element used in the screws proved ineffective in controlling the problem. Rather, a re-design of the extruder screws was required to prevent generation of these extended-form granules.

Entities:  

Keywords:  Continuous granulation; controlled-release; foam; rolling; twin screw extruder

Mesh:

Substances:

Year:  2014        PMID: 24467440     DOI: 10.3109/03639045.2013.879723

Source DB:  PubMed          Journal:  Drug Dev Ind Pharm        ISSN: 0363-9045            Impact factor:   3.225


  3 in total

Review 1.  Advances in Twin-Screw Granulation Processing.

Authors:  Uttom Nandi; Vivek Trivedi; Steven A Ross; Dennis Douroumis
Journal:  Pharmaceutics       Date:  2021-04-27       Impact factor: 6.321

2.  Twin Screw Granulation: An Investigation of the Effect of Barrel Fill Level.

Authors:  Sushma V Lute; Ranjit M Dhenge; Agba D Salman
Journal:  Pharmaceutics       Date:  2018-06-01       Impact factor: 6.321

Review 3.  Continuous Twin Screw Granulation: A Review of Recent Progress and Opportunities in Formulation and Equipment Design.

Authors:  Christoph Portier; Chris Vervaet; Valérie Vanhoorne
Journal:  Pharmaceutics       Date:  2021-05-07       Impact factor: 6.321

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.