Radiation exposure to nuclear medicine staff involved in PET/CT practice in Serbia.

V Antic1, O Ciraj-Bjelac2, J Stankovic3, D Arandjic3, N Todorovic4, S Lucic5.   

Abstract

The purpose of this work is to evaluate the radiation exposure to nuclear medicine (NM) staff in the two positron emission tomography-computed tomography centres in Serbia and to investigate the possibilities for dose reduction. Dose levels in terms of Hp(10) for whole body and Hp(0.07) for hands of NM staff were assessed using thermoluminescence and electronic personal dosemeters. The assessed doses per procedure in terms of Hp(10) were 4.2-7 and 5-6 μSv, in two centres, respectively, whereas the extremity doses in terms of Hp(0.07) in one of the centres was 34-126 μSv procedure(-1). The whole-body doses per unit activity were 17-19 and 21-26 μSv GBq(-1) in two centres, respectively, and the normalised finger dose in one centre was 170-680 μSv GBq(-1). The maximal estimated annual whole-body doses in two centres were 3.4 and 2.0 mSv, while the corresponding extremity dose in the later one was 45 mSv. Improvements as introduction of automatic dispensing system and injection and optimisation of working practice resulted in dose reduction ranging from 12 up to 67 %.
© The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Mesh:

Substances:

Year:  2014        PMID: 24464817     DOI: 10.1093/rpd/ncu001

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  Effect of dosimeter's position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)F-FDG preparation for PET/CT.

Authors:  Fabien Salesses; Paul Perez; Aline E Maillard; Julie Blanchard; Sabine Mallard; Laurence Bordenave
Journal:  EJNMMI Phys       Date:  2016-08-05

2.  Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry.

Authors:  S Zargan; P Ghafarian; A Shabestani Monfared; A A Sharafi; M Bakhshayeshkaram; M R Ay
Journal:  J Biomed Phys Eng       Date:  2017-03-01

3.  Using Monte Carlo methods for Hp(0.07) values assessment during the handling of 18F-FDG.

Authors:  Łukasz Albiniak; Małgorzata Wrzesień
Journal:  Radiat Environ Biophys       Date:  2020-07-29       Impact factor: 1.925