Literature DB >> 24464257

Intra-arterial ultra low iodine CT angiography of renal transplant arteries.

Christian E Althoff1, Rolf W Günther, Bernd Hamm, Matthias Rief.   

Abstract

PURPOSE: This study was designed to evaluate the technical feasibility and the image quality of intra-arterial 320-row CT angiography (ia-CTA) in the detection of transplant renal artery stenosis (TRAS) using a very low dose of contrast agent.
METHODS: Evaluation of ia-CTA using a 4F catheter in ten patients with impaired renal transplant function and suspected TRAS. Average amount of contrast agent applied was 10 ± 3.7 ml standard deviation (SD). Patient serum creatinine levels had been monitored for 72 h. TRAS was detected and graded (1: less than 20 %; 2: 20-49 %; 3: 50-74 %; 4: 75-99 %; 5: total occlusion) and presence of kinking was recorded. Attenuation and vessel delineation were parameters for image quality analysis of the renal arterial supply, divided into four segments. Subjective image quality.
RESULTS: Ia-CTA of the renal transplant was technically successful in all patients, revealing relevant stenoses in 7 of 10 patients. Serum creatinine levels before and after ia-CTA were 2.71 ± 1.46 and 2.56 ± 1.39 mg/dl, respectively. None of the patients developed signs of contrast-induced nephropathy within 72 h. Subjective image quality was excellent in all four segments, rated by two separate readers. No segment was found to be nondiagnostic. Mean attenuation values in the arterial segments ranged between 754 and 987 Hounsfield units.
CONCLUSIONS: Wide detector ia-CTA for the diagnosis of TRAS is feasible using very low doses of contrast agent and results in high image quality.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24464257     DOI: 10.1007/s00270-014-0838-9

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  3 in total

1.  Intraarterial CT Angiography Using Ultra Low Volume of Iodine Contrast - Own Experiences.

Authors:  Jerzy Garcarek; Jacek Kurcz; Maciej Guziński; Mirosław Banasik; Marcin Miś; Tomasz Gołębiowski
Journal:  Pol J Radiol       Date:  2015-07-05

2.  Visualization of the renal artery in kidney transplant patients using time-resolved computed tomography angiography.

Authors:  Svensson-Marcial Anders; Genberg Helena; Brehmer Katharina; Themudo Raquel; Brismar B Torkel
Journal:  Acta Radiol Open       Date:  2021-10-01

3.  Intra-arterial computed tomography angiography with ultra-low volume of iodine contrast and stent implantation in transplant renal artery stenosis in terms of contrast-induced kidney injury - a preliminary report.

Authors:  Agata Szczurowska; Mirosław Banasik; Jacek Kurcz; Marcin Miś; Katarzyna Nowańska; Katarzyna Madziarska; Oktawia Mazanowska; Magdalena Krajewska; Jerzy Garcarek; Maciej Guziński
Journal:  Pol J Radiol       Date:  2020-04-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.