Literature DB >> 24463779

Evaluation of a method for the assessment of anterior acetabular coverage and hip joint space width.

Romuald Ferre1, Emmanuel Gibon, Moussa Hamadouche, Antoine Feydy, Jean-Luc Drapé.   

Abstract

OBJECTIVE: The false-profile view (FP) is an oblique view of the acetabulum and a true lateral view of femur and joint. It evaluates anterior and posterior hip joint space width (JSW) and anterior acetabular coverage using the vertical-center margin angle (VCA). The biplanar slot scanner (SS) allows simultaneous bilateral acquisitions of oblique views of hip joints. The aim of this work was to compare SS versus FP for the evaluation of VCA and JSW and to test its reproducibility and validity.
MATERIALS AND METHODS: A prospective study of 28 patients (55 hips) with hip pain was performed from November 2011 until May 2012. Two readers measured VCA and JSW. JSW was normalized by the diameter of the femoral head for each technique. The radiation exposure was recorded and compared between the two modalities. Student's t test and the Pearson's correlation assessed the agreement between SS and FP. The intraclass correlation coefficient (ICC) was used to assess the interobserver agreement.
RESULTS: The mean VCA angle was 32.1° (± 7.1°) and 30.3° (± 8.5°) with FP and SS, respectively. The coefficient of correlation was 0.90 (p < 0.01). The coefficient of correlation of normalized JSW was 0.83, 0.85, and 0.87 at anterior, vertical, and posterior points, respectively). The ICC was between 0.69 and 0.81 for each modality. The mean radiation exposure was 1.33 (± 0.02) mGy versus 8.69 (±0.04) mGy for FP and SS, respectively (p < 0.0001).
CONCLUSIONS: SS has the potential advantages of simultaneous bilateral acquisition, higher standardization, and is less irradiating. SS is reliable for coxometry.

Entities:  

Mesh:

Year:  2014        PMID: 24463779     DOI: 10.1007/s00256-014-1815-8

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  11 in total

1.  Evaluation of the 'Lequesne's false profile' of the hip in patients with hip osteoarthritis.

Authors:  T Conrozier; M Bochu; J Gratacos; M Piperno; P Mathieu; E Vignon
Journal:  Osteoarthritis Cartilage       Date:  1999-05       Impact factor: 6.576

2.  Anatomical and radiological correlation of Lequesne's "false profile".

Authors:  L Fabeck; D Farrokh; C Behets; P Delincé
Journal:  Surg Radiol Anat       Date:  2002-07-19       Impact factor: 1.246

3.  The anterior center edge angle in Lequesne's false profile view: interrater correlation, dependence on pelvic tilt and correlation to anterior acetabular coverage in the sagital plane. A cadaver study.

Authors:  P O Zingg; C M L Werner; A Sukthankar; M Zanetti; B Seifert; C Dora
Journal:  Arch Orthop Trauma Surg       Date:  2008-07-16       Impact factor: 3.067

Review 4.  Standardized way for imaging of the sagittal spinal balance.

Authors:  Gérard Morvan; Philippe Mathieu; Valérie Vuillemin; Henri Guerini; Philippe Bossard; Frédéric Zeitoun; Marc Wybier
Journal:  Eur Spine J       Date:  2011-08-10       Impact factor: 3.134

5.  New method for measuring acetabular component positioning with EOS imaging: feasibility study on dry bone.

Authors:  Alexandre Journé; Jérome Sadaka; Claire Bélicourt; Alain Sautet
Journal:  Int Orthop       Date:  2012-09-05       Impact factor: 3.075

6.  EOS imaging of the human pelvis: reliability, validity, and controlled comparison with radiography.

Authors:  Bernd Bittersohl; Joana Freitas; Daniela Zaps; Matthew R Schmitz; James D Bomar; Abd R Muhamad; Harish S Hosalkar
Journal:  J Bone Joint Surg Am       Date:  2013-05-01       Impact factor: 5.284

7.  Computed tomography for preoperative planning in minimal-invasive total hip arthroplasty: radiation exposure and cost analysis.

Authors:  Alexander Huppertz; Sebastian Radmer; Patrick Asbach; Ralf Juran; Carsten Schwenke; Gerd Diederichs; Bernd Hamm; Martin Sparmann
Journal:  Eur J Radiol       Date:  2009-12-22       Impact factor: 3.528

8.  Diagnostic imaging of spinal deformities: reducing patients radiation dose with a new slot-scanning X-ray imager.

Authors:  Sylvain Deschênes; Guy Charron; Gilles Beaudoin; Hubert Labelle; Josée Dubois; Marie-Claude Miron; Stefan Parent
Journal:  Spine (Phila Pa 1976)       Date:  2010-04-20       Impact factor: 3.468

9.  The faux profil (oblique view) of the hip in the standing position. Contribution to the evaluation of osteoarthritis of the adult hip.

Authors:  M G Lequesne; J D Laredo
Journal:  Ann Rheum Dis       Date:  1998-11       Impact factor: 19.103

10.  Reproducibility and sensitivity to change of various methods to measure joint space width in osteoarthritis of the hip: a double reading of three different radiographic views taken with a three-year interval.

Authors:  Emmanuel Maheu; Christian Cadet; Marc Marty; Maxime Dougados; Salah Ghabri; Isabelle Kerloch; Bernard Mazières; Tim D Spector; Eric Vignon; Michel G Lequesne
Journal:  Arthritis Res Ther       Date:  2005-10-05       Impact factor: 5.156

View more
  1 in total

1.  Acetabular coverage differs between standing and supine positions: model-based assessment of low-dose biplanar radiographs and comparison with CT.

Authors:  Benjamin Fritz; Christoph A Agten; Franca K Boldt; Patrick O Zingg; Christian W A Pfirrmann; Reto Sutter
Journal:  Eur Radiol       Date:  2019-03-22       Impact factor: 5.315

  1 in total