John V Mitsios1, Adrain McClellan2, Sarah Brown3, Ann M Gronowski4. 1. Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, MO 63110, USA. 2. Barnes Jewish Hospital, Department of Laboratories, St. Louis, MO 63110, USA. 3. Department of Pediatrics, Washington University School of Medicine, St. Louis, MO 63110, USA. 4. Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, MO 63110, USA. Electronic address: gronowski@wustl.edu.
Abstract
OBJECTIVE: Measurement of human chorionic gonadotropin (hCG) and α-fetoprotein (AFP) in cerebrospinal fluid (CSF) can aid in the diagnosis of germ cell tumors (GCTs). Matrix effects can influence test results when alternative sample types are used, therefore, alternative sample types should always be validated before clinical use. Here we have validated the Advia® Centaur total hCG and AFP methods for use with CSF. We also performed a retrospective review of 5years of CSF hCG and AFP measurements sent out from our institution. DESIGN AND METHODS: Both hCG and AFP concentrations were measured using the ADVIA Centaur® total hCG or AFP assay. RESULTS: The Centaur hCG and AFP assays, performed on CSF, had intra- and inter-assay imprecisions <10.2% CV. The assays were linear over a dynamic range of 10-1000IU/L for hCG and 10-1000μg/L for AFP. Retrospective chart review confirmed that GCTs have a male predominance and are diagnosed most frequently in the second decade of life. The data also illustrate the importance of measuring both serum and CSF concentrations as CSF can be elevated in the absence of serum elevations. CONCLUSIONS: The Centaur total hCG and AFP methods accurately quantify hCG and AFP in CSF.
OBJECTIVE: Measurement of humanchorionic gonadotropin (hCG) and α-fetoprotein (AFP) in cerebrospinal fluid (CSF) can aid in the diagnosis of germ cell tumors (GCTs). Matrix effects can influence test results when alternative sample types are used, therefore, alternative sample types should always be validated before clinical use. Here we have validated the Advia® Centaur total hCG and AFP methods for use with CSF. We also performed a retrospective review of 5years of CSF hCG and AFP measurements sent out from our institution. DESIGN AND METHODS: Both hCG and AFP concentrations were measured using the ADVIA Centaur® total hCG or AFP assay. RESULTS: The Centaur hCG and AFP assays, performed on CSF, had intra- and inter-assay imprecisions <10.2% CV. The assays were linear over a dynamic range of 10-1000IU/L for hCG and 10-1000μg/L for AFP. Retrospective chart review confirmed that GCTs have a male predominance and are diagnosed most frequently in the second decade of life. The data also illustrate the importance of measuring both serum and CSF concentrations as CSF can be elevated in the absence of serum elevations. CONCLUSIONS: The Centaur total hCG and AFP methods accurately quantify hCG and AFP in CSF.
Authors: Johan M Kros; Dana M Mustafa; Lennard J M Dekker; Peter A E Sillevis Smitt; Theo M Luider; Ping-Pin Zheng Journal: Neuro Oncol Date: 2014-09-24 Impact factor: 12.300
Authors: Alicia R Jones; Alan McNeil; Christopher Yates; Bala Krishnamurthy; Peter S Hamblin Journal: Endocrinol Diabetes Metab Case Rep Date: 2018-02-23