Literature DB >> 24462943

Determination of ⁹⁰Sr and ²¹⁰Pb in sludge samples using a LOV-MSFIA system and liquid scintillation counting.

M Mola1, J Avivar2, A Nieto1, A Peñalver1, C Aguilar1, L Ferrer2, V Cerdà3, F Borrull4.   

Abstract

There has been increasing interest recently in the capacity of water treatment plants to concentrate and eliminate radionuclides from raw water. As the normal operation in these plants generates high quantities of sludge, which can be considered a naturally occurring radioactive material, it is important to gather information about its radiological content. Therefore, in order to determine the activity values of two radioactive beta emitters with minimal sample manipulation, an automated lab-on-valve and multisyringe flow injection system has been developed to achieve the sequential preconcentration and separation of (90)Sr and (210)Pb using an extraction chromatographic resin (Sr-spec). Activities of both isotopes were measured by liquid scintillation counting (LSC). The developed method was validated by analyzing three samples from three different intercomparison exercises and good Z-score values (between 0.1 and 1) and trueness values (between 10% and 17%) were obtained. The method was then also satisfactorily applied to sludge samples taken from a Spanish drinking water treatment plant which treats water from the Ebro River. The proposed method offers advantages over existing methods as it allows the sequential separation of both isotopes, simply by changing the elution conditions and using a semi-automated approach. Therefore, the method is less time consuming and environmentally friendly.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  (210)Pb; (90)Sr; Lab-on-valve – multisyringe flow injection analysis; Liquid scintillation counting; Sludge

Year:  2013        PMID: 24462943     DOI: 10.1016/j.apradiso.2013.11.123

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  2 in total

1.  Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level.

Authors:  Victor Vicente Vilas; Sylvain Millet; Miguel Sandow; Laura Aldave de Las Heras
Journal:  J Vis Exp       Date:  2018-06-06       Impact factor: 1.355

Review 2.  Analytical Methods for the Determination of 90Sr and 239,240Pu in Environmental Samples.

Authors:  Ningjie Zhong; Lili Li; Xiaofan Yang; Yonggang Zhao
Journal:  Molecules       Date:  2022-03-15       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.