Literature DB >> 24462125

Accuracy of maxillary repositioning in two-jaw surgery with conventional articulator model surgery versus virtual model surgery.

T-G Kwon1, J-W Choi2, H-M Kyung3, H-S Park3.   

Abstract

The purpose of this study was to compare the accuracy of maxillary repositioning using the recently introduced computerized virtual model surgery (VMS) with conventional articulator model surgery (AMS). Forty-two patients who had undergone bimaxillary surgery were investigated retrospectively in this study. The patients were divided into two groups: conventional AMS (n = 23) and VMS (n = 19) for intermediate splint fabrication in maxillary positioning. Planned surgical movements and actual postsurgical changes of the lateral and frontal cephalometric measurements were compared. Although variations from the planned surgical movements were relatively small, both methods had statistically significant errors in some of the linear measurements. Both groups had a similar range of errors. The overall absolute mean discrepancy between the planned and actual surgical movements for the linear measurements was 1.17 mm (0-3.6 mm) in AMS and 0.95 mm (0-3.2 mm) in VMS. Of the total measurements, measurements reflecting a surgical discrepancy of more than 2 mm or 2° comprised 12.0% of the cases in AMS and 7.9% in VMS. The surgical accuracy of maxillary positioning with VMS was comparable to conventional AMS. Because VMS has the definitive advantage of eliminating the complex laboratory step and shortening the laboratory time, this can be accepted as an alternative to AMS.
Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  accuracy; articulator model surgery; maxillary osteotomy; virtual model surgery

Mesh:

Year:  2014        PMID: 24462125     DOI: 10.1016/j.ijom.2013.11.009

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  5 in total

1.  Laboratorial Comparative Study of the Accuracy Between Virtual Planning and Erickson's Platform.

Authors:  Maysa Nogueira de Barros Melo; Ítalo Miranda do Vale Pereira; Alexander Tadeu Sverzut; Cássio Edvard Sverzut; Alexandre Elias Trivellato
Journal:  J Maxillofac Oral Surg       Date:  2022-01-17

2.  Comparison of time and cost between conventional surgical planning and virtual surgical planning in orthognathic surgery in Korea.

Authors:  Si-Yeon Park; Dae-Seok Hwang; Jae-Min Song; Uk-Kyu Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2019-09-12

3.  Randomized Clinical Trial of the Accuracy of Patient-Specific Implants versus CAD/CAM Splints in Orthognathic Surgery.

Authors:  Biao Li; Hongpu Wei; Tengfei Jiang; Yifeng Qian; Tianjia Zhang; Hongbo Yu; Lei Zhang; Xudong Wang
Journal:  Plast Reconstr Surg       Date:  2021-11-01       Impact factor: 5.169

4.  Comparison of time and cost between conventional surgical planning and virtual surgical planning in orthognathic surgery in Korea.

Authors:  Si-Yeon Park; Dae-Seok Hwang; Jae-Min Song; Uk-Kyu Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2021-06-21

5.  The Accuracy of Jaws Repositioning in Bimaxillary Orthognathic Surgery with Traditional Surgical Planning Compared to Digital Surgical Planning in Skeletal Class III Patients: A Retrospective Observational Study.

Authors:  Martina Barone; Alberto De Stefani; Ugo Baciliero; Giovanni Bruno; Antonio Gracco
Journal:  J Clin Med       Date:  2020-06-12       Impact factor: 4.241