Literature DB >> 24461828

Highly sensitive and selective determination of pyrazinamide at poly-L-methionine/reduced graphene oxide modified electrode by differential pulse voltammetry in human blood plasma and urine samples.

Srikanth Cheemalapati1, Balamurugan Devadas1, Shen-Ming Chen2.   

Abstract

In this current study we used electrochemically active film which contains poly-L-methionine (PMET) and electrochemically reduced graphene oxide (ERGO) on glassy carbon electrode (GCE) for pyrazinamide (PZM) detection. The electrocatalytic response of analyte at PMET/ERGO/GCE film was measured using both cyclic voltammetry (CV) and differential pulse voltammetry (DPV). In addition, electrochemical impedance studies revealed that the smaller R(ct) value observed at PMET/ERGO film modified GCE which authenticates its good conductivity and faster electron transfer rate. The prepared PMET/ERGO/GCE film exhibits excellent DPV response towards PZM and the reduction peak current increased linearly with respect to PZM concentration in the linear range between 0.4 μM to 1129 μM with a sensitivity of 0.266 μA μM(-1) cm(-2). Real sample studies were carried out in human blood plasma and urine samples, which offered good recovery and revealed the promising practicality of the sensor for PZM detection. The proposed sensor displayed a good selectivity, repeatability, sensitivity with appreciable consistency and good reproducibility. In addition, the proposed electrochemical sensor showed good results towards the commercial pharmaceutical PZM samples.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Blood plasma; Differential pulse voltammetry; Electrochemically reduced graphene oxide; Methionine; Pyrazinamide; Reduction

Mesh:

Substances:

Year:  2013        PMID: 24461828     DOI: 10.1016/j.jcis.2013.11.084

Source DB:  PubMed          Journal:  J Colloid Interface Sci        ISSN: 0021-9797            Impact factor:   8.128


  2 in total

Review 1.  Combining electrochemical sensors with miniaturized sample preparation for rapid detection in clinical samples.

Authors:  Natinan Bunyakul; Antje J Baeumner
Journal:  Sensors (Basel)       Date:  2014-12-30       Impact factor: 3.576

2.  Highly Sensitive Determination of Tenofovir in Pharmaceutical Formulations and Patients Urine-Comparative Electroanalytical Studies Using Different Sensing Methods.

Authors:  Natalia Festinger; Kaja Spilarewicz-Stanek; Kamila Borowczyk; Dariusz Guziejewski; Sylwia Smarzewska
Journal:  Molecules       Date:  2022-03-19       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.