PURPOSES: The primary aim of the study was to investigate a 1-year success rate of early-loaded bone level implants with a chemically modified sand-blasted, large grit, acid-etched surface (SLActive®, Institut Straumann AG, Basel, Switzerland) in the posterior maxilla. Secondary objectives included stability of these implants and peri-implant bone level. MATERIALS AND METHODS: Bone level® implants (Institut Straumann AG) inserted into premolar and/or molar maxillary sites were loaded after 6 weeks of healing. The implants were monitored for 1 year using the following outcome measures: implant success, primary and secondary stability, and peri-implant bone level. RESULTS: Out of 37 implants placed in 13 patients, 36 reached sufficient stability and were early loaded, whereas one underwent a delayed loading protocol. One-year success rate of early-loaded implants was 100%. Implant stability at baseline was 71.7 ± 5. 6 to be steadily increased thereafter up to 1 year (80.3 ± 3.3), except at 2 weeks when a nonsignificant decrease was noticed (71.9 ± 3.9). Continuous and significant bone loss was observed, reaching 0.4 ± 0.1 mm in the first postoperative year. CONCLUSION: Bone level implants with the SLActive surface placed into low-density bone and loaded after 6 weeks of healing can predictably achieve and maintain a successful tissue integration.
PURPOSES: The primary aim of the study was to investigate a 1-year success rate of early-loaded bone level implants with a chemically modified sand-blasted, large grit, acid-etched surface (SLActive®, Institut Straumann AG, Basel, Switzerland) in the posterior maxilla. Secondary objectives included stability of these implants and peri-implant bone level. MATERIALS AND METHODS: Bone level® implants (Institut Straumann AG) inserted into premolar and/or molar maxillary sites were loaded after 6 weeks of healing. The implants were monitored for 1 year using the following outcome measures: implant success, primary and secondary stability, and peri-implant bone level. RESULTS: Out of 37 implants placed in 13 patients, 36 reached sufficient stability and were early loaded, whereas one underwent a delayed loading protocol. One-year success rate of early-loaded implants was 100%. Implant stability at baseline was 71.7 ± 5. 6 to be steadily increased thereafter up to 1 year (80.3 ± 3.3), except at 2 weeks when a nonsignificant decrease was noticed (71.9 ± 3.9). Continuous and significant bone loss was observed, reaching 0.4 ± 0.1 mm in the first postoperative year. CONCLUSION: Bone level implants with the SLActive surface placed into low-density bone and loaded after 6 weeks of healing can predictably achieve and maintain a successful tissue integration.
Authors: Rainde Naiara Rezende de Jesus; Eunice Carrilho; Pedro V Antunes; Amílcar Ramalho; Camilla Christian Gomes Moura; Andreas Stavropoulos; Darceny Zanetta-Barbosa Journal: Int J Implant Dent Date: 2018-09-27