Literature DB >> 24461107

CT-based three-dimensional kinematic comparison of dart-throwing motion between wrists with malunited distal radius and contralateral normal wrists.

S Lee1, Y S Kim2, C S Park2, K G Kim2, Y H Lee3, H S Gong3, H J Lee3, G H Baek4.   

Abstract

AIM: To compare motion of the capitate, scaphoid, and lunate in wrists with a malunited distal radius and contralateral normal wrists during dart-throwing motion (DTM) by three-dimensional kinematic studies using computed tomography (CT) images.
MATERIALS AND METHODS: CT was performed simultaneously on both wrists in six patients with a unilateral distal radius malunion at three stepwise positions simulating DTM. Using volume registration technique, the kinematic variables of helical axis motion of the capitate, scaphoid, and lunate were calculated and compared between both wrists. The helical motion of the capitate was also evaluated in a scaphoid- and lunate-based coordinate system.
RESULTS: Among the average rotation and translation of the scaphoid, lunate, and capitate during DTM, only the average rotation of the capitate was significantly different between the uninjured (88.9°) and the injured (70°) wrist (p = 0.0075). Rotation of the capitate relative to the scaphoid (26.3° versus 37.8°, p = 0.029) or lunate (39.2° versus 59.3°, p = 0.028) was smaller in the malunited wrist. The centres of helical axis motion of the three carpal bones were located more dorsally and radially in the injured wrist.
CONCLUSIONS: The present study showed that decreased DTM in wrists with a distal radius malunion resulted from decreased midcarpal motion. The present study of the capitate, scaphoid, and lunate in wrists with distal radius malunion might be the first to present a 3D kinematic analysis of the effect of distal radius malunion on the carpal bones.
Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24461107     DOI: 10.1016/j.crad.2013.09.023

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  2 in total

1.  Triquetral Motion Is Limited In Vivo After Lunocapitate Arthrodesis.

Authors:  Thorsten Schriever; Henrik Olivecrona; Maria Wilcke
Journal:  J Hand Surg Glob Online       Date:  2019-10-25

2.  Accuracy of manual and automatic placement of an anatomical coordinate system for the full or partial radius in 3D space.

Authors:  Marieke G A de Roo; Johannes G G Dobbe; Abbas Peymani; Anne D van der Made; Simon D Strackee; Geert J Streekstra
Journal:  Sci Rep       Date:  2020-05-15       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.