Literature DB >> 24459607

Validity, Reliability, and Sensitivity of a 3D Vision Sensor-based Upper Extremity Reachable Workspace Evaluation in Neuromuscular Diseases.

Jay J Han1, Gregorij Kurillo2, R Ted Abresch1, Alina Nicorici1, Ruzena Bajcsy2.   

Abstract

INTRODUCTION: One of the major challenges in the neuromuscular field has been lack of upper extremity outcome measures that can be useful for clinical therapeutic efficacy studies. Using vision-based sensor system and customized software, 3-dimensional (3D) upper extremity motion analysis can reconstruct a reachable workspace as a valid, reliable and sensitive outcome measure in various neuromuscular conditions where proximal upper extremity range of motion and function is impaired.
METHODS: Using a stereo-camera sensor system, 3D reachable workspace envelope surface area normalized to an individual's arm length (relative surface area: RSA) to allow comparison between subjects was determined for 20 healthy controls and 9 individuals with varying degrees of upper extremity dysfunction due to neuromuscular conditions. All study subjects were classified based on Brooke upper extremity function scale. Right and left upper extremity reachable workspaces were determined based on three repeated measures. The RSAs for each frontal hemi-sphere quadrant and total reachable workspaces were determined with and without loading condition (500 gram wrist weight). Data were analyzed for assessment of the developed system and validity, reliability, and sensitivity to change of the reachable workspace outcome.
RESULTS: The mean total RSAs of the reachable workspace for the healthy controls and individuals with NMD were significantly different (0.586 ± 0.085 and 0.299 ± 0.198 respectively; p<0.001). All quadrant RSAs were reduced for individuals with NMDs compared to the healthy controls and these reductions correlated with reduced upper limb function as measured by Brooke grade. The upper quadrants of reachable workspace (above the shoulder level) demonstrated greatest reductions in RSA among subjects with progressive severity in upper extremity impairment. Evaluation of the developed outcomes system with the Bland-Altman method demonstrated narrow 95% limits of agreement (LOA) around zero indicating high reliability. In addition, the intraclass correlation coefficient (ICC) was 0.97. Comparison of the reachable workspace with and without loading condition (wrist weight) showed significantly greater RSA reduction in the NMD group than the control group (p<0.012), with most of the workspace reduction occurring in the ipsilateral upper quadrant relative to the tested arm (p<0.001). Reduction in reachable workspace due to wrist weight was most notable in those subjects with NMD with marginal strength reserve and moderate degree of impairment (Brooke = 2) rather than individuals with mild upper extremity impairment (Brooke = 1) or individuals who were more severely impaired (Brooke =3). DISCUSSION: The developed reachable workspace evaluation method using scalable 3D vision technology appears promising as an outcome measure system for clinical studies. A rationally-designed combination of upper extremity outcome measures including a region-specific global upper extremity outcome measure, such as the reachable workspace, complemented by targeted disease- or function-specific endpoints, may be optimal for future clinical efficacy trials.

Entities:  

Year:  2013        PMID: 24459607      PMCID: PMC3871415          DOI: 10.1371/currents.md.f63ae7dde63caa718fa0770217c5a0e6

Source DB:  PubMed          Journal:  PLoS Curr        ISSN: 2157-3999


  20 in total

1.  Normative and validation studies of the Nine-hole Peg Test with children.

Authors:  Y A Smith; E Hong; C Presson
Journal:  Percept Mot Skills       Date:  2000-06

2.  The development of antisense oligonucleotide therapies for Duchenne muscular dystrophy: report on a TREAT-NMD workshop hosted by the European Medicines Agency (EMA), on September 25th 2009.

Authors:  F Muntoni
Journal:  Neuromuscul Disord       Date:  2010-03-26       Impact factor: 4.296

3.  An objective and standardized test of hand function.

Authors:  R H Jebsen; N Taylor; R B Trieschmann; M J Trotter; L A Howard
Journal:  Arch Phys Med Rehabil       Date:  1969-06       Impact factor: 3.966

4.  Clinical trial in Duchenne dystrophy. I. The design of the protocol.

Authors:  M H Brooke; R C Griggs; J R Mendell; G M Fenichel; J B Shumate; R J Pellegrino
Journal:  Muscle Nerve       Date:  1981 May-Jun       Impact factor: 3.217

5.  A kinematic model of the shoulder complex to evaluate the arm-reachable workspace.

Authors:  N Klopcar; M Tomsic; J Lenarcic
Journal:  J Biomech       Date:  2006-01-04       Impact factor: 2.712

6.  Reliability of quantitative muscle testing in healthy children and in children with Duchenne muscular dystrophy using a hand-held dynamometer.

Authors:  W A Stuberg; W K Metcalf
Journal:  Phys Ther       Date:  1988-06

7.  Accuracy and robustness of Kinect pose estimation in the context of coaching of elderly population.

Authors:  Stepán Obdrzálek; Gregorij Kurillo; Ferda Ofli; Ruzena Bajcsy; Edmund Seto; Holly Jimison; Michael Pavel
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

8.  Towards harmonisation of outcome measures for DMD and SMA within TREAT-NMD; report of three expert workshops: TREAT-NMD/ENMC workshop on outcome measures, 12th--13th May 2007, Naarden, The Netherlands; TREAT-NMD workshop on outcome measures in experimental trials for DMD, 30th June--1st July 2007, Naarden, The Netherlands; conjoint Institute of Myology TREAT-NMD meeting on physical activity monitoring in neuromuscular disorders, 11th July 2007, Paris, France.

Authors:  E Mercuri; A Mayhew; F Muntoni; S Messina; V Straub; G J Van Ommen; T Voit; E Bertini; K Bushby
Journal:  Neuromuscul Disord       Date:  2008-09-24       Impact factor: 4.296

9.  Development and application of stereo camera-based upper extremity workspace evaluation in patients with neuromuscular diseases.

Authors:  Gregorij Kurillo; Jay J Han; Richard T Abresch; Alina Nicorici; Posu Yan; Ruzena Bajcsy
Journal:  PLoS One       Date:  2012-09-17       Impact factor: 3.240

10.  Proof of concept of the ability of the kinect to quantify upper extremity function in dystrophinopathy.

Authors:  Linda P Lowes; Lindsay N Alfano; Brent A Yetter; Lise Worthen-Chaudhari; William Hinchman; Jordan Savage; Patrick Samona; Kevin M Flanigan; Jerry R Mendell
Journal:  PLoS Curr       Date:  2013-03-14
View more
  12 in total

1.  Reachable workspace reflects dynamometer-measured upper extremity strength in facioscapulohumeral muscular dystrophy.

Authors:  Jay J Han; Evan De Bie; Alina Nicorici; Richard T Abresch; Ruzena Bajcsy; Gregorij Kurillo
Journal:  Muscle Nerve       Date:  2015-06-19       Impact factor: 3.217

2.  Modifying Kinect placement to improve upper limb joint angle measurement accuracy.

Authors:  Na Jin Seo; Mojtaba F Fathi; Pilwon Hur; Vincent Crocher
Journal:  J Hand Ther       Date:  2016-10-18       Impact factor: 1.950

3.  Upper extremity 3-dimensional reachable workspace analysis in dystrophinopathy using Kinect.

Authors:  Jay J Han; Gregorij Kurillo; Richard T Abresch; Evan De Bie; Alina Nicorici; Ruzena Bajcsy
Journal:  Muscle Nerve       Date:  2015-06-03       Impact factor: 3.217

4.  Reachable workspace in facioscapulohumeral muscular dystrophy (FSHD) by Kinect.

Authors:  Jay J Han; Gregorij Kurillo; Richard T Abresch; Evan de Bie; Alina Nicorici; Ruzena Bajcsy
Journal:  Muscle Nerve       Date:  2014-11-19       Impact factor: 3.217

5.  Reachable workspace and performance of upper limb (PUL) in duchenne muscular dystrophy.

Authors:  Jay J Han; Evan de Bie; Alina Nicorici; Richard T Abresch; Colleen Anthonisen; Ruzena Bajcsy; Gregorij Kurillo; Craig M Mcdonald
Journal:  Muscle Nerve       Date:  2015-12-29       Impact factor: 3.217

6.  Capturing Upper Limb Gross Motor Categories Using the Kinect® Sensor.

Authors:  Na Jin Seo; Vincent Crocher; Egli Spaho; Charles R Ewert; Mojtaba F Fathi; Pilwon Hur; Sara A Lum; Elizabeth M Humanitzki; Abigail L Kelly; Viswanathan Ramakrishnan; Michelle L Woodbury
Journal:  Am J Occup Ther       Date:  2019 Jul/Aug

7.  A Movement Monitor Based on Magneto-Inertial Sensors for Non-Ambulant Patients with Duchenne Muscular Dystrophy: A Pilot Study in Controlled Environment.

Authors:  Anne-Gaëlle Le Moing; Andreea Mihaela Seferian; Amélie Moraux; Mélanie Annoussamy; Eric Dorveaux; Erwan Gasnier; Jean-Yves Hogrel; Thomas Voit; David Vissière; Laurent Servais
Journal:  PLoS One       Date:  2016-06-07       Impact factor: 3.240

8.  Development of a 3D workspace shoulder assessment tool incorporating electromyography and an inertial measurement unit-a preliminary study.

Authors:  Navid Aslani; Siamak Noroozi; Philip Davenport; Richard Hartley; Mihai Dupac; Philip Sewell
Journal:  Med Biol Eng Comput       Date:  2017-11-11       Impact factor: 2.602

9.  Motion sensor-acquired reachable workspace correlates with patient-reported upper extremity activities of daily living (ADL) function in facioscapulohumeral dystrophy.

Authors:  Maya N Hatch; Gregorij Kurillo; Vicky Chan; Jay J Han
Journal:  Muscle Nerve       Date:  2020-12-01       Impact factor: 3.852

10.  Clinical trial readiness to solve barriers to drug development in FSHD (ReSolve): protocol of a large, international, multi-center prospective study.

Authors:  Samantha LoRusso; Nicholas E Johnson; Michael P McDermott; Katy Eichinger; Russell J Butterfield; Elena Carraro; Kiley Higgs; Leann Lewis; Karlien Mul; Sabrina Sacconi; Valeria A Sansone; Perry Shieh; Baziel van Engelen; Kathryn Wagner; Leo Wang; Jeffrey M Statland; Rabi Tawil
Journal:  BMC Neurol       Date:  2019-09-10       Impact factor: 2.474

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.