Literature DB >> 24459251

Ten year follow-up of pyrocarbon implants for proximal interphalangeal joint replacement.

L Reissner1, S Schindele1, S Hensler2, M Marks2, D B Herren3.   

Abstract

Results of anatomical resurfacing of the proximal interphalangeal joint using pyrocarbon implants showed reasonable clinical results with a high radiographic migration rate. The aim was to investigate the subjective, clinical, and radiographic results 10 years following surgery, and to compare them with our 2-year follow-up data. We re-evaluated 12 patients with 15 proximal interphalangeal implants on average 9.7 years after surgery. Pain significantly improved from 7.6 on a visual analogue scale pre-operatively to 1.4 at 2 years, and to 0.7 at the final follow-up. The mean total range of motion in all replaced joints was 36° pre-operatively and 39° at the 2-year follow-up, but had decreased significantly to 29° at 10 years. We saw one implant migration in addition to the eight migrated implants we already found 2 years after surgery. The moderate clinical results, combined with the high migration rate, mean that we no longer use this kind of implant.
© The Author(s) 2013.

Entities:  

Keywords:  Pyrocarbon; arthritis; arthroplasty; proximal interphalangeal joint

Mesh:

Substances:

Year:  2014        PMID: 24459251     DOI: 10.1177/1753193413511922

Source DB:  PubMed          Journal:  J Hand Surg Eur Vol        ISSN: 0266-7681


  8 in total

Review 1.  Radiographic and surgical considerations in arthritis surgery of the hand.

Authors:  Violeta Nikac; Philip Blazar; Brandon Earp; Barbara N Weissman
Journal:  Skeletal Radiol       Date:  2017-02-14       Impact factor: 2.199

Review 2.  A Systematic Review of Different Implants and Approaches for Proximal Interphalangeal Joint Arthroplasty.

Authors:  Michiro Yamamoto; Sunitha Malay; Yuki Fujihara; Lin Zhong; Kevin C Chung
Journal:  Plast Reconstr Surg       Date:  2017-05       Impact factor: 4.730

3.  Trends in Primary Proximal Interphalangeal Joint System and Revisions for Osteoarthritis of the Hand in the Medicare Database.

Authors:  Michael O Madden; Joseph R Palmer; Bijan J Ameri; Rushabh M Vakharia; Jacob Landes; Martin W Roche
Journal:  Hand (N Y)       Date:  2019-03-21

4.  Outcomes of Surface Replacement Proximal Interphalangeal Joint Arthroplasty Through a Volar Approach: A Prospective Study.

Authors:  Thomas E Trumble; Dennis J Heaton
Journal:  Hand (N Y)       Date:  2016-08-03

5.  [Research progress in artificial metacarpophalangeal joint and interphalangeal joint prostheses].

Authors:  Ling Yao; Chuan Li; Jun Li
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-10-15

Review 6.  Proximal interphalangeal (PIP) joint replacements with pyrolytic carbon implants in the hand.

Authors:  Massimo Ceruso; Sandra Pfanner; Christian Carulli
Journal:  EFORT Open Rev       Date:  2017-03-13

7.  Functional Outcomes for Meniscal Allograft Interposition Arthroplasty of the Hand.

Authors:  Meghan C McCullough; Raquel Minasian; Kylie Tanabe; Sandra Rodriguez; David Kulber
Journal:  Plast Reconstr Surg Glob Open       Date:  2021-04-20

8.  Systematic review of the introduction, early phase study and evaluation of pyrocarbon proximal interphalangeal joint arthroplasty.

Authors:  Paul Welford; Natalie S Blencowe; Emily Pardington; Conor S Jones; Jane M Blazeby; Barry G Main
Journal:  PLoS One       Date:  2021-10-19       Impact factor: 3.752

  8 in total