Could mini-PET be used to instead of 4 h original-PET to assess peritoneal permeability in children on peritoneal dialysis?

Funda Baştuğ1, Ismail Dursun, Jale Dursun, Zübeyde Gündüz, Demet Günay, Sibel Yel, Ruhan Düşünsel, Sibel Bolat, Kenan Yılmaz, Sebahat Tülpar, Hakan Poyrazoglu.   

Abstract

BACKGROUND: Original peritoneal equilibration test (PET) is an implementation that requires hard work for peritoneal dialysis (PD) staff. Therefore, several authors have attempted to validate short and fast PET protocols, with controversial results. The aim of this study was to evaluate the concordance between the mini-PET and original PET in children.
METHODS: In 26 stable continuous ambulatory PD patients, we performed an original PET with 2.27% (4 h) and a mini-PET with 3.86% glucose PD fluid (1 h) and compared ultrafiltration (UF) and small solute transports obtained with the two methods.
RESULTS: Twenty-six children, 14 males, mean age 11.4 ± 5.6 (range 2.5-19 years), were included. Meantime on PD at time of enrollment was 35.2 ± 24.5 months (range 6-84 months). Based on the 4-h creatinine D/P data, the number of the patients within each transport category was as follow: high, 5; average, 18; low, 3. Kappa test showed a significant concordance between original PET and mini-PET (k=0.610). Based on the 4-h glucose D/D0 data, the number of the patients within each transport category was as follow: high, 5; average, 17; low, 4. Kappa test showed a moderate agreement between original PET and mini-PET (0.514, p=0.000). When Pearson correlation analysis between original PET and mini-PET was performed, there were significant positive correlations between original 2.27% PET and mini-PET (r=0.720, p=0.000, r=0.638, p=0.000, respectively). When comparing the numeric results of mini-PET and 4 h of original PET for D/Creatinine, by simple regression analysis, we found statistically significant correlation among PETs.
CONCLUSIONS: In this study, we showed concordance between the mini-PET and original PET. The 3.86% mini-PET is simple and fast methods to assess free water transport. This also gives information about total UF and small solute transports and it is in good agreement with the original PET.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24456204     DOI: 10.3109/0886022X.2013.879368

Source DB:  PubMed          Journal:  Ren Fail        ISSN: 0886-022X            Impact factor:   2.606


  2 in total

1.  Comparative Assessment of Peritoneal Membrane Characteristics in Patients on Continuous Ambulatory Peritoneal Dialysis Using Standard Peritoneal Equilibration Test and Fast Peritoneal Equilibration Test.

Authors:  Aman Gupta; Pradeep Deshpande; G Sridhar; J Ramashankar
Journal:  Indian J Nephrol       Date:  2021-02-08

2.  Comparison of three PET methods to assess peritoneal membrane transport.

Authors:  R F Romani; J Waniewski; L Kruger; B Lindholm; M M Nascimento
Journal:  Braz J Med Biol Res       Date:  2019-08-05       Impact factor: 2.590

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.