Literature DB >> 24451883

New-design dental implants: a 1-year prospective clinical study of 344 consecutively placed implants comparing immediate loading versus delayed loading and flapless versus full-thickness flap.

Eliezer Meizi, Mamraev Meir, Zvi Laster.   

Abstract

PURPOSE: This study compared the 1-year success rates of immediately loaded dental implants to delayed loaded implants, regardless of the surgical technique (flapless or conventional full-thickness flap) and regardless of extraction time. It also examined whether the surgical technique had an influence on the success rate of the immediately loaded implants.
MATERIALS AND METHODS: A total of 344 dental implants, some with a new expanded winged-thread design, were placed in 155 patients; 53% of the implants were immediately loaded. Of the immediately loaded implants, 68.9% were placed with a flapless surgical technique and 88% were placed in extraction sites. Pocket depth, mobility, bleeding on probing, presence of erythema, pain, or radiolucency around the implants, as well as clinical findings, were recorded. Implants were followed from placement through definitive restoration. Descriptive, univariate, and multivariate analyses using clustered marginal approach of the Cox proportional hazards model were applied.
RESULTS: Of the 344 implants in the study, 10 (2.9%) failures were recorded, 7 of which were immediately loaded; however, there was no significant difference in failure rates between the immediate and delayed loading groups. Seven of the implants that failed were placed with a flapless (extraction site) technique; however, there was no significant difference in the failure rates between the flapless versus full-thickness flap technique in immediately loaded implants.
CONCLUSIONS: The clinical success of immediately loaded implants after 1 year showed no difference from the success rate of delayed loaded implants. The implantation procedure (flapless versus conventional flap) or extraction time also had no influence on the success rate of the immediately loaded implants.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24451883     DOI: 10.11607/jomi.te37

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

1.  In vivo Comparison of Crestal Bone Heights Following Implant Placement with "Flapless" and "Flap" Techniques in the Sites of Early Loaded Implants.

Authors:  Suhani Kukreja Pahuja; Pooja Negi; Anjali Singh; Gangesh Bahadur Singh; Deepa Rayast; Manisha Minz
Journal:  J Pharm Bioallied Sci       Date:  2021-06-05

2.  Flapless versus conventional flapped dental implant surgery: a meta-analysis.

Authors:  Bruno Ramos Chrcanovic; Tomas Albrektsson; Ann Wennerberg
Journal:  PLoS One       Date:  2014-06-20       Impact factor: 3.240

Review 3.  Augmentation versus No Augmentation for Immediate Postextraction Implants.

Authors:  Huda Hamed Basher Mohamed; Asma M Serag Eldien; Amr Zahran
Journal:  Int J Dent       Date:  2018-10-16

4.  Clinical and radiographic evaluation of new dental implant system: Results of a 3-year prospective study.

Authors:  Seçil Karakoca Nemli; Merve Bankoğlu Güngör; Cemal Aydın; Handan Yılmaz; Bilge Turhan Bal; Yeliz Kaşko Arıcı
Journal:  J Dent Sci       Date:  2015-05-15       Impact factor: 2.080

Review 5.  Comparative evaluation of crestal bone level by flapless and flap techniques for implant placement: Systematic review and meta-analysis.

Authors:  Krishankumar Lahoti; Sayali Dandekar; Jaykumar Gade; Megha Agrawal
Journal:  J Indian Prosthodont Soc       Date:  2021 Oct-Dec

Review 6.  Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis.

Authors:  Adam Ibrahim; Bruno Ramos Chrcanovic
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.