Clinical and radiologic experience with moderately rough oxidized titanium implants: up to 10 years of retrospective follow-up.

Alessandro Pozzi, Priamo Mura.   

Abstract

PURPOSE: The long-term success of machined-surface implants is well documented, whereas the reliability of the moderately rough oxidized implant surface has not been definitively assessed in the long term. The aim of this retrospective study was to assess the long-term clinical and radiologic outcomes of moderately rough oxidized implants supporting fixed prostheses.
MATERIALS AND METHODS: Seventy-three consecutive patients needing an implant-supported restoration received 1 to 11 implants each (n=167). All implants (82 cylindric and 85 tapered-body implants) had a self-tapping design and a moderately rough oxidized surface and were immediately loaded (n=48) or loaded after a delay (n=113). Patients were followed for up to 10 years. Outcomes were implant and prosthetic survival rates, peri-implant bone level changes, bleeding on probing, and plaque and gingival indices.
RESULTS: One patient (one implant) dropped out. Seventy-two patients (166 implants) were followed for at least 8 years (mean, 8.82 years; range, 8.0 to 10.4 years. No implants or prostheses were lost, resulting in a cumulative implant and prosthetic survival rate of 100% after up to 10 years in function. At the final follow-up, the accumulated mean marginal bone loss values were -1.72±1.53 mm (n=27) and -1.27±1.67 mm (n=44) for cylindric and tapered implants, respectively, with no statistically significant difference. Bleeding on probing was 12.1%. The cumulative plaque score was 19.7%; 83.8% of patients showed normal gingiva, 10.1% displayed mild inflammation, and 6.1% showed moderate inflammation.
CONCLUSION: This retrospective study of 73 patients treated with either cylindric or tapered-body moderately rough oxidized implants and followed for up to 10 years demonstrated good treatment outcomes with regard to implant survival, marginal bone changes, and soft tissue conditions.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24451866     DOI: 10.11607/jomi.3306

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  3 in total

1.  Clinical and radiological outcomes of novel digital workflow and dynamic navigation for single-implant immediate loading in aesthetic zone: 1-year prospective case series.

Authors:  Alessandro Pozzi; Lorenzo Arcuri; Paolo Carosi; Alessandra Nardi; Joseph Kan
Journal:  Clin Oral Implants Res       Date:  2021-09-08       Impact factor: 5.021

Review 2.  Recent advances in dental implants.

Authors:  Do Gia Khang Hong; Ji-Hyeon Oh
Journal:  Maxillofac Plast Reconstr Surg       Date:  2017-11-05

Review 3.  Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis.

Authors:  Adam Ibrahim; Bruno Ramos Chrcanovic
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.