Literature DB >> 24449733

Image quality influences the assessment of left ventricular function: an intraoperative comparison of five 2-dimensional echocardiographic methods with real-time 3-dimensional echocardiography as a reference.

Manuel Grossgasteiger1, Maximilian D Hien, Bastian Graser, Helmut Rauch, Johann Motsch, Matthias Gondan, Christian Rosendal.   

Abstract

OBJECTIVES: Transesophageal echocardiography has become a standard tool for evaluating left ventricular function during cardiac surgery. However, the image quality varies widely between patients and examinations. The aim of this study was to investigate the influence of the image quality on 5 commonly used 2-dimensional methods.
METHODS: Transesophageal real-time 3-dimensional echocardiography (3DE) served as a reference. Left ventricular function was evaluated in 63 patients with sufficient real-time 3DE image quality. The image quality was rated using the ratio of the visualized border divided by the total endocardial border. These ratings were used to generate groups of poor (0%-40%), fair (41%-70%), and good (71%-100%) image quality. The ejection fraction (EF), end-diastolic volume, and end-systolic volume were analyzed by the Simpson method of disks (biplane and monoplane), eyeball method, Teichholz method, and speckle-tracking method. Furthermore, the fractional area change was determined. Each correlation with real-time 3DE was evaluated.
RESULTS: Correlations of the EF and volumes, respectively, as determined by long-axis view methods increased with improving image quality: the Simpson biplane method was found to be the most accurate method, with good image quality for the EF (r = 0.946) and volumes (end-diastolic volume, r = 0.962; end-systolic volume, r = 0.989). Correlations of the EF and fractional area change by short-axis view methods decreased with improving image quality, with the Teichholz EF found to be most accurate with poor (r = 0.928) in contrast to good (r = 0.699) image quality.
CONCLUSIONS: With good image quality, the Simpson biplane method is the most accurate 2-dimensional method for assessing the left ventricular EF. Short-axis view methods, especially the Teichholz method yield better correlations with poor image quality. The eyeball method was unaffected by image quality.

Entities:  

Keywords:  Simpson method of disks; Teichholz method; fractional area change; image quality; intraoperative 3-dimensional transesophageal echocardiography; speckle tracking; vascular ultrasound

Mesh:

Year:  2014        PMID: 24449733     DOI: 10.7863/ultra.33.2.297

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  3 in total

1.  Effect of ingesting carbohydrate only or carbohydrate plus casein protein hydrolysate during a multiday cycling race on left ventricular function, plasma volume expansion and cardiac biomarkers.

Authors:  Tanja Oosthuyse; Andrew N Bosch; Aletta M E Millen
Journal:  Eur J Appl Physiol       Date:  2019-01-04       Impact factor: 3.078

2.  Nebivolol versus Carvedilol or Metoprolol in Patients Presenting with Acute Myocardial Infarction Complicated by Left Ventricular Dysfunction.

Authors:  Mehmet Ozaydin; Habil Yucel; Sule Kocyigit; Mehmet Koray Adali; Fatih Aksoy; Fatih Kahraman; Bayram Ali Uysal; Dogan Erdogan; Ercan Varol; Abdullah Dogan
Journal:  Med Princ Pract       Date:  2016-05-10       Impact factor: 1.927

3.  Speckle tracking stress echocardiography in children: interobserver and intraobserver reproducibility and the impact of echocardiographic image quality.

Authors:  Lucia Wilke; Francisca E Abellan Schneyder; Markus Roskopf; Andreas C Jenke; Andreas Heusch; Kai O Hensel
Journal:  Sci Rep       Date:  2018-06-15       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.