Literature DB >> 24447958

Assessment of endometrial and subendometrial blood flow in women undergoing frozen embryo transfer cycles.

Anupa Nandi1, Wellington P Martins2, Kannamannadiar Jayaprakasan3, Jeanette S Clewes3, Bruce K Campbell3, Nicholas J Raine-Fenning4.   

Abstract

This study evaluated whether 3D power Doppler (3DPD) indices from endometrium and subendometrium can identify increases in endometrial volume/vascularity induced by exogenous oestradiol and subsequent introduction of progestogens in women undergoing frozen-thawed embryo transfer (FET). Oral oestradiol was administered at increasing doses after down-regulation to prepare the endometrium and progestogens were used for luteal support. 3DPD data sets were acquired at down-regulation, on days 5, 10 and 15 of oestradiol administration and at the time of FET. Endometrial thickness was measured using the multiplanar method and endometrial volume and blood flow from the endometrium and subendometrium were estimated using virtual organ computer-aided analysis and shell-imaging. This study evaluated 45 women at least once: 19 achieved clinical pregnancy (CP); 21 were evaluated at down-regulation (eight CP), 26 at day 5 (10 CP), 31 at day 10 (12 CP), 31 at day 15 (13 CP) and 16 at FET (seven CP). Changes were observed in all parameters between the examinations; however, differences between women who achieved CP and those who did not were not significant. 3DPD angiography is not a sufficiently sensitive tool to predict the outcome of FET. We evaluate whether 3D ultrasound using power Doppler (3DPD) indices from endometrium and subendometrium can identify predictable increases in endometrial volume and vascularity induced by serial increments in exogenous oestradiol and the subsequent introduction of progestogens in women undergoing frozen-thawed embryo transfer (FET) using hormone replacement therapy to prepare the endometrium. Oral oestradiol was administered at increasing doses after down-regulation to prepare the endometrium and progestogens were used for luteal support. 3DPD data sets of the uterus were acquired at down-regulation, on days 5, 10, and 15 of oestradiol administration, and at the time of FET. Endometrial thickness was measured. Endometrial volume and blood flow from the endometrium and subendometrium were measured using virtual organ computer-aided analysis (VOCAL) and shell imaging. This study evaluated 45 women at least once: 19 achieved clinical pregnancy (CP); 21 were evaluated at down-regulation (eight CP), 26 at day 5 (10 CP), 31 at day 10 (12 CP), 31 at day 15 (13 CP) and 16 at FET (seven CP). Changes were observed in all the parameters between the examinations; however, differences between women who achieved CP and those who did not were not significant, suggesting that quantitative 3D power Doppler angiography is not a sufficiently sensitive tool to predict the outcome of FET treatment.
Copyright © 2013 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  endometrial vascularity; frozen embryo replacement; frozen embryo transfer; frozen-thawed embryo transfer; sub endometrial blood flow; three-dimensional power Doppler

Mesh:

Substances:

Year:  2013        PMID: 24447958     DOI: 10.1016/j.rbmo.2013.11.004

Source DB:  PubMed          Journal:  Reprod Biomed Online        ISSN: 1472-6483            Impact factor:   3.828


  3 in total

1.  Assessment of uterine receptivity by endometrial and sub-endometrial blood flow using SlowflowHD in hormone prepared frozen embryo transfer cycles: a pilot study.

Authors:  Seifeldin Sadek; Tamar Matitashvili; Alessandra Kovac; Hadi Ramadan; Laurel Stadtmauer
Journal:  J Assist Reprod Genet       Date:  2022-04-14       Impact factor: 3.357

2.  Placental vascularization alterations in hypertensive disorders complicating pregnancy (HDCP) and small for gestational age with HDCP using three-dimensional power doppler in a prospective case control study.

Authors:  Ting Yuan; Ting Zhang; Zhen Han
Journal:  BMC Pregnancy Childbirth       Date:  2015-10-05       Impact factor: 3.007

Review 3.  3D Power Doppler vascular indices as a novel technique in assessing the outcome of minimally invasive techniques in uterine fibroids treatment.

Authors:  Anna Stępniak; Piotr Czuczwar
Journal:  Prz Menopauzalny       Date:  2017-12-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.