Literature DB >> 24446801

The effect of probe placement on inter-trial variability when using the Cutometer MPA 580.

James P Bonaparte1, Jeffson Chung.   

Abstract

There is limited data independently assessing the optimal use of the Cutometer MPA580. The purpose of this study is to test the hypothesis that the assessment of elastic recoil is significantly different when utilizing two different probe placement protocols. In protocol A, four trials were performed, in which the probe was removed from the skin between trials. In protocol B, the probe was not removed from the skin between trials. Fifty-four patients were enrolled and all completed the testing. When assessing elasticity (Ua/Uf), the inter-class correlation was 0.83 for protocol A and 0.48 for protocol B (p <0.001). There was no significant difference between individual trials for protocol A. Trial one of protocol B was significantly different (p < 0.001) than trials 2-4 for protocol B. Trial one of protocol B was not significantly different than any trial in protocol A. The results of this study suggest that the method in which a clinician performs repeated measure testing has a significant effect on the outcome measures when using the Cutometer. Removing the probe between trials appears to result in measures with higher reliability.

Entities:  

Mesh:

Year:  2014        PMID: 24446801     DOI: 10.3109/03091902.2013.876111

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  4 in total

1.  Assessment of Pliability and Elasticity of the External Nasal Skin in Patients With Unilateral Nasal Valve Collapse: A Static Biomechanical Evaluation.

Authors:  James P Bonaparte; Ross Campbell
Journal:  JAMA Facial Plast Surg       Date:  2018-12-01       Impact factor: 4.611

2.  Standardizing Dimensionless Cutometer Parameters to Determine In Vivo Elasticity of Human Skin.

Authors:  Darren B Abbas; Christopher V Lavin; Evan J Fahy; Michelle Griffin; Nicholas Guardino; Megan King; Kellen Chen; P Hermann Lorenz; Geoffrey C Gurtner; Michael T Longaker; Arash Momeni; Derrick C Wan
Journal:  Adv Wound Care (New Rochelle)       Date:  2021-10-08       Impact factor: 4.730

3.  The reliability of non-invasive biophysical outcome measures for evaluating normal and hyperkeratotic foot skin.

Authors:  Farina Hashmi; Ciaran Wright; Christopher Nester; Sharon Lam
Journal:  J Foot Ankle Res       Date:  2015-07-09       Impact factor: 2.303

4.  Investigating the intra- and inter-rater reliability of a panel of subjective and objective burn scar measurement tools.

Authors:  K C Lee; A Bamford; F Gardiner; A Agovino; B Ter Horst; J Bishop; A Sitch; L Grover; A Logan; N S Moiemen
Journal:  Burns       Date:  2019-07-19       Impact factor: 2.744

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.