Literature DB >> 24445083

Reliability of laser Doppler flowmetry curve reading for measurement of toe and ankle pressures: intra- and inter-observer variation.

C Høyer1, J P D Paludan2, S Pavar2, J A Biurrun Manresa3, L J Petersen4.   

Abstract

OBJECTIVES: To assess the intra- and inter-observer variation in laser Doppler flowmetry curve reading for measurement of toe and ankle pressures.
METHODS: A prospective single blinded diagnostic accuracy study was conducted on 200 patients with known or suspected peripheral arterial disease (PAD), with a total of 760 curve sets produced. The first curve reading for this study was performed by laboratory technologists blinded to clinical clues and previous readings at least 3 months after the primary data sampling. The pressure curves were later reassessed following another period of at least 3 months. Observer agreement in diagnostic classification according to TASC-II criteria was quantified using Cohen's kappa. Reliability was quantified using intra-class correlation coefficients, coefficients of variance, and Bland-Altman analysis.
RESULTS: The overall agreement in diagnostic classification (PAD/not PAD) was 173/200 (87%) for intra-observer (κ = .858) and 175/200 (88%) for inter-observer data (κ = .787). Reliability analysis confirmed excellent correlation for both intra- and inter-observer data (ICC all ≥.931). The coefficients of variance ranged from 2.27% to 6.44% for intra-observer and 2.39% to 8.42% for inter-observer data. Subgroup analysis showed lower observer-variation for reading of toe pressures in patients with diabetes and/or chronic kidney disease than patients not diagnosed with these conditions. Bland-Altman plots showed higher variation in toe pressure readings than ankle pressure readings.
CONCLUSIONS: This study shows substantial intra- and inter-observer agreement in diagnostic classification and reading of absolute pressures when using laboratory technologists as observers. The study emphasises that observer variation for curve reading is an important factor concerning the overall reproducibility of the method. Our data suggest diabetes and chronic kidney disease have an influence on toe pressure reproducibility.
Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Ankle brachial index; Clinical laboratory techniques; Diagnostic test; Laser Doppler flowmetry; Peripheral arterial disease; Toe brachial index

Mesh:

Year:  2014        PMID: 24445083     DOI: 10.1016/j.ejvs.2013.11.016

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  2 in total

1.  Peripheral arterial disease screening and diagnostic practice: A scoping review.

Authors:  Cornelius M Donohue; Joseph V Adler; Laura L Bolton
Journal:  Int Wound J       Date:  2019-11-03       Impact factor: 3.315

2.  Impairment of microcirculation and vascular responsiveness in adolescents with primary Raynaud phenomenon.

Authors:  Bernadett Mosdósi; Kata Bölcskei; Zsuzsanna Helyes
Journal:  Pediatr Rheumatol Online J       Date:  2018-03-23       Impact factor: 3.054

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.