Literature DB >> 24443658

Hierarchical Linear Models for Energy Prediction using Inertial Sensors: A Comparative Study for Treadmill Walking.

Harshvardhan Vathsangam1, B Adar Emken2, E Todd Schroeder3, Donna Spruijt-Metz2, Gaurav S Sukhatme1.   

Abstract

Walking is a commonly available activity to maintain a healthy lifestyle. Accurately tracking and measuring calories expended during walking can improve user feedback and intervention measures. Inertial sensors are a promising measurement tool to achieve this purpose. An important aspect in mapping inertial sensor data to energy expenditure is the question of normalizing across physiological parameters. Common approaches such as weight scaling require validation for each new population. An alternative is to use a hierarchical approach to model subject-specific parameters at one level and cross-subject parameters connected by physiological variables at a higher level. In this paper, we evaluate an inertial sensor-based hierarchical model to measure energy expenditure across a target population. We first determine the optimal movement and physiological features set to represent data. Periodicity based features are more accurate (p<0.1 per subject) when generalizing across populations. Weight is the most accurate parameter (p<0.1 per subject) measured as percentage prediction error. We also compare the hierarchical model with a subject-specific regression model and weight exponent scaled models. Subject-specific models perform significantly better (p<0.1 per subject) than weight exponent scaled models at all exponent scales whereas the hierarchical model performed worse than both. However, using an informed prior from the hierarchical model produces similar errors to using a subject-specific model with large amounts of training data (p<0.1 per subject). The results provide evidence that hierarchical modeling is a promising technique for generalized prediction energy expenditure prediction across a target population in a clinical setting.

Entities:  

Keywords:  Accelerometer; Bayesian Linear regression; Gyroscope; Hierarchical Linear Model

Year:  2013        PMID: 24443658      PMCID: PMC3891737          DOI: 10.1007/s12652-012-0150-y

Source DB:  PubMed          Journal:  J Ambient Intell Humaniz Comput


  14 in total

1.  Scaling physiological measurements for individuals of different body size.

Authors:  A M Nevill; R Ramsbottom; C Williams
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1992

2.  Energy estimation of treadmill walking using on-body accelerometers and gyroscopes.

Authors:  Harshvardhan Vathsangam; B Emken; E Schroeder; Donna Spruijt-Metz; Gaurav S Sukhatme
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

3.  Normalization of energy expenditure data for differences in body mass or composition in children and adolescents.

Authors:  Issa Zakeri; Maurice R Puyau; Anne L Adolph; Firoz A Vohra; Nancy F Butte
Journal:  J Nutr       Date:  2006-05       Impact factor: 4.798

4.  A novel method for using accelerometer data to predict energy expenditure.

Authors:  Scott E Crouter; Kurt G Clowers; David R Bassett
Journal:  J Appl Physiol (1985)       Date:  2005-12-01

5.  An artificial neural network model of energy expenditure using nonintegrated acceleration signals.

Authors:  Megan P Rothney; Megan Neumann; Ashley Béziat; Kong Y Chen
Journal:  J Appl Physiol (1985)       Date:  2007-07-19

6.  The influence of body weight on energy expenditure during walking on a road and on a treadmill.

Authors:  C H Wyndham; W H van der Walt; A J van Rensburg; G G Rogers; N B Strydom
Journal:  Int Z Angew Physiol       Date:  1971

Review 7.  The energy expenditure of normal and pathologic gait.

Authors:  R L Waters; S Mulroy
Journal:  Gait Posture       Date:  1999-07       Impact factor: 2.840

8.  Scaling for the VO2-to-body size relationship among children and adults.

Authors:  D M Rogers; B L Olson; J H Wilmore
Journal:  J Appl Physiol (1985)       Date:  1995-09

9.  Energy cost of treadmill and floor walking at self-selected paces.

Authors:  M E Pearce; D A Cunningham; A P Donner; P A Rechnitzer; G M Fullerton; J H Howard
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1983

10.  Determining energy expenditure from treadmill walking using hip-worn inertial sensors: an experimental study.

Authors:  Harshvardhan Vathsangam; Adar Emken; E Todd Schroeder; Donna Spruijt-Metz; Gaurav S Sukhatme
Journal:  IEEE Trans Biomed Eng       Date:  2011-06-16       Impact factor: 4.538

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.