Impact of subsidence on clinical outcomes and radiographic fusion rates in anterior cervical discectomy and fusion: a systematic review.

Isaac O Karikari1, Deeptee Jain, Timothy Ryan Owens, Oren Gottfried, Tiffany R Hodges, Shahid M Nimjee, Carlos A Bagley.   

Abstract

STUDY
DESIGN: Systematic review.
OBJECTIVE: To provide a systematic review of published literature on the impact of subsidence on clinical outcomes and radiographic fusion rates after anterior cervical discectomy and fusion with plates or without plates.
BACKGROUND: Subsidence of interbody implants is common after anterior cervical spine fusions. The impact of subsidence on fusion rates and clinical outcomes is unknown.
METHODS: Systematic literature review on published articles on anterior cervical discectomy and fusion, which objectively measured graft subsidence, radiographic fusion rates, and clinical outcomes between April 1966 and December 2010.
RESULTS: A total of 35 articles that measured subsidence and provided fusion rates and/or clinical outcomes were selected for inclusion. The mean subsidence rate ranged from 19.3% to 42.5%. The rate of subsidence based on the type of implant ranged from 22.8% to 35.9%. The incidence of subsidence was not impacted by the type of implant (P=0.98). The overall fusion rate of the combined studies was 92.8% and was not impacted by subsidence irrespective of subsidence definition or the measurement technique used (P=0.19). Clinical outcomes were evaluated in 27 of 35 studies with all studies reporting an improvement in patient outcomes postoperatively.
CONCLUSIONS: Subsidence irrespective of the measurement technique or definition does not appear to have an impact on successful fusion and/or clinical outcomes. A validated definition and standard measurement technique for subsidence is needed to determine the actual incidence of subsidence and its impact on radiographic and clinical outcomes.

Entities:  

Mesh:

Year:  2014        PMID: 24441059     DOI: 10.1097/BSD.0b013e31825bd26d

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  21 in total

1.  Meta-Analysis Comparing Zero-Profile Spacer and Anterior Plate in Anterior Cervical Fusion.

Authors:  Jun Dong; Meng Lu; Teng Lu; Baobao Liang; Junkui Xu; Jun Zhou; Hongjun Lv; Jie Qin; Xuan Cai; Sihua Huang; Haopeng Li; Dong Wang; Xijing He
Journal:  PLoS One       Date:  2015-06-11       Impact factor: 3.240

Review 2.  Locking stand-alone cage versus anterior plate construct in anterior cervical discectomy and fusion: a systematic review and meta-analysis based on randomized controlled trials.

Authors:  Yachao Zhao; Sidong Yang; Yachong Huo; Zhaohui Li; Dalong Yang; Wenyuan Ding
Journal:  Eur Spine J       Date:  2020-08-08       Impact factor: 3.134

3.  The application of a new type of titanium mesh cage in hybrid anterior decompression and fusion technique for the treatment of continuously three-level cervical spondylotic myelopathy.

Authors:  Xiaowei Liu; Yu Chen; Haisong Yang; Tiefeng Li; Haidong Xu; Bin Xu; Deyu Chen
Journal:  Eur Spine J       Date:  2016-11-24       Impact factor: 3.134

4.  Influence of cervical bone mineral density on cage subsidence in patients following stand-alone anterior cervical discectomy and fusion.

Authors:  Christopher Brenke; Martin Dostal; Johann Scharf; Christel Weiß; Kirsten Schmieder; Martin Barth
Journal:  Eur Spine J       Date:  2014-12-19       Impact factor: 3.134

5.  Cage deviation in the subaxial cervical spine in relation to implant position in the sagittal plane.

Authors:  Klaus Christian Mende; Sven Oliver Eicker; Friedrich Weber
Journal:  Neurosurg Rev       Date:  2017-04-04       Impact factor: 3.042

6.  PEEK versus titanium-coated PEEK cervical cages: fusion rate.

Authors:  Bartosz Godlewski; Adam Bebenek; Maciej Dominiak; Grzegorz Karpinski; Piotr Cieslik; Tomasz Pawelczyk
Journal:  Acta Neurochir (Wien)       Date:  2022-04-26       Impact factor: 2.216

7.  A single center retrospective clinical evaluation of anterior cervical discectomy and fusion comparing allograft spacers to silicon nitride cages.

Authors:  Micah W Smith; Daniel R Romano; Bryan J McEntire; B Sonny Bal
Journal:  J Spine Surg       Date:  2018-06

Review 8.  Interbody Fusions in the Lumbar Spine: A Review.

Authors:  Ravi Verma; Sohrab Virk; Sheeraz Qureshi
Journal:  HSS J       Date:  2020-01-13

9.  Symptomatic pseudarthrosis requiring revision surgery after 1- or 2-level ACDF with plating: peek versus allograft.

Authors:  Abdul Fettah Buyuk; Ikemefuna Onyekwelu; Christian J Gaffney; Amir A Mehbod; John M Dawson; Timothy A Garvey; Benjamin Mueller; James D Schwender
Journal:  J Spine Surg       Date:  2020-12

10.  Risk factors for subsidence in anterior cervical fusion with stand-alone polyetheretherketone (PEEK) cages: a review of 82 cases and 182 levels.

Authors:  Ting-Hsien Kao; Chen-Hao Wu; Yu-Ching Chou; Hsien-Te Chen; Wen-Hsien Chen; Hsi-Kai Tsou
Journal:  Arch Orthop Trauma Surg       Date:  2014-08-07       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.