Microbial adherence to cosmetic contact lenses.

Ka Yin Chan1, Pauline Cho2, Maureen Boost3.   

Abstract

AIM: To investigate whether cosmetic contact lenses (CCL) with surface pigments affect microbial adherence.
METHOD: Fifteen brands of CCL were purchased from optical, non-optical retail outlets, and via the Internet. A standardized rub-off test was performed on each CCL (five lenses per brand) to confirm the location of the pigments. The rub-off test comprised gentle rubbing on the surfaces of each CCL with wetted cotton buds for a maximum of 20 rubs per surface. A new set of CCL (five lenses per brand) were incubated in Pseudomonas aeruginosa overnight. Viable counts of adhered bacteria were determined by the number of colony-forming units (CFU) on agar media on each lens. The adherence of P. aeruginosa as well as Staphylococcus aureus and Serratia marcescens to three brands of CCL (A-C) (five lenses per brand) were also compared to their adherences on their clear counterparts.
RESULTS: Only two of the 15 brands of CCL tested (brands B and C) had pigments that did not detach with the rub-off test. The remaining 13 brands of CCL all failed the rub-off test and these lenses showed higher P. aeruginosa adherence (8.7 × 10(5)-1.9 × 10(6) CFU/lens). Brands B and C lenses showed at least six times less bacterial adhesion than the other 13 brands. Compared to their clear counterparts, bacterial adherence to brands B and C lenses did not differ significantly, whereas brand A lenses showed significantly higher adherence.
CONCLUSION: Surface pigments on CCL resulted in significantly higher bacterial adherence.
Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bacterial adherence; Coloured contact lenses; Cosmetic contact lenses; Decorative contact lenses; Microbial adherence

Mesh:

Substances:

Year:  2014        PMID: 24440107     DOI: 10.1016/j.clae.2013.12.002

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  13 in total

1.  Development of ciprofloxacin-loaded contact lenses using fluorous chemistry.

Authors:  Guoting Qin; Zhiling Zhu; Siheng Li; Alison M McDermott; Chengzhi Cai
Journal:  Biomaterials       Date:  2017-01-31       Impact factor: 12.479

Review 2.  A review of cosmetic contact lens infections.

Authors:  Chris H L Lim; Fiona Stapleton; Jodhbir S Mehta
Journal:  Eye (Lond)       Date:  2018-11-01       Impact factor: 3.775

3.  Scanning Electron Microscopy Findings With Energy-Dispersive X-ray Investigations of Cosmetically Tinted Contact Lenses.

Authors:  Fumika Hotta; Hiroshi Eguchi; Shoji Imai; Tatsuro Miyamoto; Sayaka Mitamura-Aizawa; Yoshinori Mitamura
Journal:  Eye Contact Lens       Date:  2015-09       Impact factor: 2.018

4.  Adhesion of Acanthamoeba on Cosmetic Contact Lenses.

Authors:  Seung Mok Lee; Ji Eun Lee; Da In Lee; Hak Sun Yu
Journal:  J Korean Med Sci       Date:  2018-01-22       Impact factor: 2.153

5.  Development of uracil-DNA-glycosylase-supplemented loop-mediated isothermal amplification coupled with nanogold probe (UDG-LAMP-AuNP) for specific detection of Pseudomonas aeruginosa.

Authors:  Orapan Manajit; Siwaporn Longyant; Paisarn Sithigorngul; Parin Chaivisuthangkura
Journal:  Mol Med Rep       Date:  2018-02-02       Impact factor: 2.952

6.  Identifying Pigment Enclosure in Cosmetic Contact Lenses.

Authors:  Vrushali Korde; Kimberly McDow; Dominique Rollins; Rowena Stinchcomb; Heather Esposito
Journal:  Eye Contact Lens       Date:  2020-07       Impact factor: 3.152

7.  Comparison of the Lubricity and Surface Roughness of 5 Cosmetic Contact Lenses.

Authors:  Charis Lau; Samuele Tosatti; Michelle Mundorf; Kingsley Ebare; Kathrine Osborn Lorenz
Journal:  Eye Contact Lens       Date:  2018-11       Impact factor: 2.018

8.  Influence of Contact Lens Materials and Cleaning Procedures on Bacterial Adhesion and Biofilm Formation.

Authors:  Auemphon Mordmuang; Lunla Udomwech; Kulwadee Karnjana
Journal:  Clin Ophthalmol       Date:  2021-06-08

9.  Monocular Diplopia: An Optical Correction Modality.

Authors:  Haile W Alemu; Preetam Kumar
Journal:  Case Rep Ophthalmol       Date:  2021-06-11

Review 10.  Therapeutic Contact Lenses with Polymeric Vehicles for Ocular Drug Delivery: A Review.

Authors:  Seung Woo Choi; Jaeyun Kim
Journal:  Materials (Basel)       Date:  2018-07-01       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.