Periprosthetic femoral fractures (PFF) are a serious complication after total hip arthroplasty. Plate fixation with screws perforating the cement mantle is a common treatment option. The study objective was to investigate hip stem stability and cement mantle integrity under dynamic loading. A cemented hip stem was implanted in 17 composite femur models. Nine bone models were osteotomised just distal to the stem and fixed with a polyaxial locking plate the other eight constructs served as the control group. All specimens were tested in a bi-axial material testing machine (100000 cycles). There were no statistically significant differences in axial nor in medial (varus) stem migration. No cement cracks were detected in both groups. Plate fixation of a PFF with a stable, cemented prosthesis did not lead to cement mantle failure in this in vitro study.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  cement mantle failure; hip stem stability; periprosthetic fracture fixation; polyaxial locking Plate; total hip arthroplasty

Mesh:

Substances:

Year:  2013        PMID: 24439999     DOI: 10.1016/j.arth.2013.12.015

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

1.  Minimally invasive surgery with locking plate for periprosthetic femoral fractures: technical note.

Authors:  Matthieu Ehlinger; Benjamin Scheibling; Michel Rahme; David Brinkert; Benoit Schenck; Antonio Di Marco; Philippe Adam; François Bonnomet
Journal:  Int Orthop       Date:  2015-08-08       Impact factor: 3.075

2.  Use of locking plates for fixation of the greater trochanter in patients with hip replacement.

Authors:  Allison K Tetreault; Brian J McGrory
Journal:  Arthroplast Today       Date:  2016-10-13

Review 3.  Additive manufactured polyether-ether-ketone implants for orthopaedic applications: a narrative review.

Authors:  Changning Sun; Jianfeng Kang; Chuncheng Yang; Jibao Zheng; Yanwen Su; Enchun Dong; Yingjie Liu; Siqi Yao; Changquan Shi; Huanhao Pang; Jiankang He; Ling Wang; Chaozong Liu; Jianhua Peng; Liang Liu; Yong Jiang; Dichen Li
Journal:  Biomater Transl       Date:  2022-06-28

Review 4.  Biomechanics of Osteoporotic Fracture Fixation.

Authors:  Marianne Hollensteiner; Sabrina Sandriesser; Emily Bliven; Christian von Rüden; Peter Augat
Journal:  Curr Osteoporos Rep       Date:  2019-12       Impact factor: 5.096

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.