Efficacy of spherical aberration correction based on contact lens power.

Shizuka Koh1, Naoyuki Maeda2, Tsunekazu Hamada3, Kohji Nishida2.   

Abstract

PURPOSE: To investigate the efficacy of spherical aberration (SA) correction with aspheric contact lenses (aspheric lenses) based on lens power, and compare the results with those of spherical contact lenses (spherical lenses).
METHODS: Ocular higher-order aberrations were measured with a wavefront sensor, in 11 myopic subjects wearing an aspheric lens (Medalist Fresh fit (PUREVISION 2 HD); Bausch+Lomb) or a spherical lens (ACUVUE Oasys; Johnson & Johnson). Six different lens powers (-7.00 diopters (D), -5.00 D, -3.00 D, -1.00 D, +1.00 D, +3.00 D) were used for all subjects. The amount of SA correction from the contact lens at each power was calculated as the difference between SA with the contact lens on-eye and SA of the eye alone.
RESULTS: For the spherical lenses, SA correction was close to 0.00 μm for the +1.00 D lens, became more positive as the labeled lens power increased and became more negative as the labeled lens power decreased. For the aspheric lenses, SA correction was consistent, from -0.15 to -0.05 μm, for all lens powers except for the -1.00 D lens. SA correction for the spherical and aspheric lenses was significantly different at -7.00 D (p=0.040), -3.00 D (p=0.015), -1.00 D (p<0.001), +1.00 D (p=0.006), and +3.00 D (p<0.001) powers.
CONCLUSION: An aspheric lens is capable of correcting SA at different lens powers, and has SA correction in the range of -0.15 to -0.05 μm over a 6mm aperture.
Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aspheric contact lens; Contact lens power; Spherical aberration

Mesh:

Year:  2014        PMID: 24439628     DOI: 10.1016/j.clae.2013.12.003

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  1 in total

1.  A lab-on-phone instrument with varifocal microscope via a liquid-actuated aspheric lens (LAL).

Authors:  Yiin-Kuen Fuh; Zheng-Hong Lai; Li-Han Kau; Hung-Jui Huang
Journal:  PLoS One       Date:  2017-06-26       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.