Literature DB >> 24439500

Development of a simple and rapid solid phase microextraction-gas chromatography-triple quadrupole mass spectrometry method for the analysis of dopamine, serotonin and norepinephrine in human urine.

Attilio Naccarato1, Emanuela Gionfriddo1, Giovanni Sindona1, Antonio Tagarelli2.   

Abstract

The work aims at developing a simple and rapid method for the quantification of dopamine (DA), serotonin (5-HT) and norepinephrine (NE) in human urine. The urinary levels of these biogenic amines can be correlated with several pathological conditions concerning heart disease, stress, neurological disorders and cancerous tumors. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) after a fast derivatization of both aliphatic amino and phenolic moieties by propyl chloroformate. The variables influencing the derivatization reaction were reliably optimized by the multivariate approach of "Experimental design". The optimal conditions were obtained by performing derivatization with 100μL of propyl chloroformate and 100μL of pyridine. The extraction ability of five commercially available SPME fibers was evaluated in univariate mode and the best results were obtained using the polyacrylate fiber. The variables affecting the efficiency of SPME analysis were again optimized by the multivariate approach of "Experimental design" and, in particular, a central composite design (CCD) was applied. The optimal values were extraction in 45min at room temperature, desorption temperature at 300°C, no addition of NaCl. Assay of derivatized analytes was performed by using a gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) system in selected reaction monitoring (SRM) acquisition. An evaluation of all analytical parameters demonstrates that the developed method provides satisfactory results. Indeed, very good linearities were achieved in the tested calibration range with correlation coefficient values of 0.9995, 0.9999 and 0.9997 for DA, 5-HT and NE, respectively. Accuracies and RSDs calculated for between-run and tested at concentrations of 30, 200, and 800μg L(-1) were in the range from 92.8% to 103.0%, and from 0.67 to 4.5%, respectively. Finally, the LOD values obtained can be considered very good (0.587, 0.381 and 1.23μg L(-1) for DA, 5-HT and NE, respectively).
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Catecholamines; Dopamine; Gas chromatography; Norepinephrine; Serotonin; Solid phase microextraction

Mesh:

Substances:

Year:  2013        PMID: 24439500     DOI: 10.1016/j.aca.2013.11.058

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  9 in total

Review 1.  Recent Trends in the Quantification of Biogenic Amines in Biofluids as Biomarkers of Various Disorders: A Review.

Authors:  Alina Plenis; Ilona Olędzka; Piotr Kowalski; Natalia Miękus; Tomasz Bączek
Journal:  J Clin Med       Date:  2019-05-09       Impact factor: 4.241

Review 2.  Current Sample Preparation Methodologies for Determination of Catecholamines and Their Metabolites.

Authors:  Nian Shi; Xinmiao Bu; Manyu Zhang; Bin Wang; Xinli Xu; Xuezhong Shi; Dilshad Hussain; Xia Xu; Di Chen
Journal:  Molecules       Date:  2022-04-22       Impact factor: 4.927

Review 3.  Optimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments.

Authors:  Elizabeth S Hecht; Ann L Oberg; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2016-03-07       Impact factor: 3.109

4.  Preparation of Methacrylate-based Polymers Modified with Chiral Resorcinarenes and Their Evaluation as Sorbents in Norepinephrine Microextraction.

Authors:  Alver Castillo-Aguirre; Mauricio Maldonado
Journal:  Polymers (Basel)       Date:  2019-08-30       Impact factor: 4.329

5.  Hemin-doped metal-organic frameworks based nanozyme electrochemical sensor with high stability and sensitivity for dopamine detection.

Authors:  Kai Kang; Beibei Wang; Xueping Ji; Yuheng Liu; Wenrui Zhao; Yaqing Du; Zhiyong Guo; Jujie Ren
Journal:  RSC Adv       Date:  2021-01-11       Impact factor: 3.361

6.  Activated Glassy Carbon Electrode as an Electrochemical Sensing Platform for the Determination of 4-Nitrophenol and Dopamine in Real Samples.

Authors:  Ali M Abdel-Aziz; Hamdy H Hassan; Ibrahim H A Badr
Journal:  ACS Omega       Date:  2022-09-13

7.  Serial Hydrolysis for the Simultaneous Analysis of Catecholamines and Steroids in the Urine of Patients with Alopecia Areata.

Authors:  Yu-Ra Lee; Bark-Lynn Lew; Woo-Young Sim; Jongki Hong; Bong-Chul Chung
Journal:  Molecules       Date:  2021-05-06       Impact factor: 4.411

8.  Simultaneous electrochemical detection of dopamine and ascorbic acid using an iron oxide/reduced graphene oxide modified glassy carbon electrode.

Authors:  Teo Peik-See; Alagarsamy Pandikumar; Huang Nay-Ming; Lim Hong-Ngee; Yusran Sulaiman
Journal:  Sensors (Basel)       Date:  2014-08-19       Impact factor: 3.576

9.  Determination of the levels of two types of neurotransmitter and the anti-migraine effects of different dose-ratios of Ligusticum chuanxiong and Gastrodia elata.

Authors:  Qiang Wang; Lan Shen; Shi-Yu Ma; Mei-Wan Chen; Xiao Lin; Yan-Long Hong; Yi Feng
Journal:  J Food Drug Anal       Date:  2015-10-16       Impact factor: 6.157

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.