Literature DB >> 24438564

[Plate related complication after mandibular reconstruction].

Shang-ping Liu1, Zhi-gang Cai2, Jie Zhang1, Jian-guo Zhang1, Yi Zhang1.   

Abstract

OBJECTIVE: To evaluate the complications and factors associated with titanium plates in mandibular reconstruction with different methods.
METHODS: A retrospective analysis of 660 patients who received primary reconstruction of the mandible was conducted. The characters of the mandibular defect and methods of reconstruction were recorded. The complications and factors associated with the reconstruction were analyzed.
RESULTS: The majority of mandibular defect was in a shape of L (n = 324 ). The total complication rate was 14.7% (97/660), which included screw loosening 5.8% (38/660), plate fracture 3.3% (22/660), plate exposure 3.8% (25/660), infection 7.4% (49/660) and malunion or ununion 2.9% (19/660). The mandibular defects reconstructed by reconstructive plates had a higher complication rate than that by bone grafts. The complication rate was 10.8% (63/586) in cases reconstructed by bone grafts with miniplates. The complications were associated with radiation therapy and diabetes. Radiation therapy had a significant effect on plate exposure.
CONCLUSIONS: Reconstruction with bone grafts can minimize the rate of plate related complication. The complications were associated with radiation therapy and diabetes.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24438564

Source DB:  PubMed          Journal:  Zhonghua Kou Qiang Yi Xue Za Zhi        ISSN: 1002-0098


  3 in total

1.  Transoral Segmental Resection and Disarticulation of Mandible with Immediate Nonvascularized Reconstruction: A Case Report.

Authors:  Hemant Gupta; Deepak Singh; Sumit Gupta; Hemant Mehra; Jasmeet Singh; Ravish Mishra
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2016-04-26

2.  Biomechanical In Vitro Study on the Stability of Patient-Specific CAD/CAM Mandibular Reconstruction Plates: A Comparison Between Selective Laser Melted, Milled, and Hand-Bent Plates.

Authors:  Robin Kasper; Karsten Winter; Sebastian Pietzka; Alexander Schramm; Frank Wilde
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2020-08-28

3.  Pre-contoured reconstruction plate fabricated via three-dimensional printed bending support.

Authors:  In-Seok Song; Jae-Jun Ryu; Young-Jun Choi; Ui-Lyong Lee
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2021-06-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.