Microbubbles are detected prior to larger bubbles following decompression.

J G Swan1, J C Wilbur, K L Moodie, S A Kane, D A Knaus, S D Phillips, T L Beach, A M Fellows, P J Magari, J C Buckey.   

Abstract

Using dual-frequency ultrasound (DFU), microbubbles (<10 μm diameter) have been detected in tissue following decompression. It is not known if these microbubbles are the precursors for B-mode ultrasound-detectable venous gas emboli (bmdVGE). The purpose of this study was to determine if microbubbles could be detected intravascularly postdecompression and to investigate the temporal relationship between microbubbles and larger bmdVGE. Anesthetized swine (n = 15) were exposed to 4.0-4.5 ATA for 2 h, followed by decompression to 0.98 ATA. Microbubble presence and VGE grade were measured using DFU and B-mode ultrasound, respectively, before and for 1 h postdecompression, approximately every 4-5 min. Microbubbles appeared in the bloodstream postdecompression, both in the presence and absence of bmdVGE. In swine without bmdVGE, microbubbles remained elevated for the entire 60-min postdecompression period. In swine with bmdVGE, microbubble signals were detected initially but then returned to baseline. Microbubbles were not detected with the sham dive. Mean bmdVGE grade increased over the length of the postdecompression data collection period. Comparison of the two response curves revealed significant differences at 5 and 10 min postdecompression, indicating that microbubbles preceded bmdVGE. These findings indicate that decompression-induced microbubbles can 1) be detected intravascularly at multiple sites, 2) appear in the presence and absence of bmdVGE, and 3) occur before bmdVGE. This supports the hypothesis that microbubbles precede larger VGE bubbles. Microbubble presence may be an early marker of decompression stress. Since DFU is a low-power ultrasonic method, it may be useful for operational diving applications.

Entities:  

Keywords:  decompression sickness; dual-frequency ultrasound; ultrasound; venous gas emboli

Mesh:

Substances:

Year:  2014        PMID: 24436299     DOI: 10.1152/japplphysiol.01156.2013

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  4 in total

1.  Hyperbaric oxygen treatment reduced the lung injury of type II decompression sickness.

Authors:  Ming Geng; Luting Zhou; Xiaohong Liu; Peifeng Li
Journal:  Int J Clin Exp Pathol       Date:  2015-02-01

Review 2.  Drug delivery systems, CNS protection, and the blood brain barrier.

Authors:  Ravi Kant Upadhyay
Journal:  Biomed Res Int       Date:  2014-07-20       Impact factor: 3.411

3.  Bubbles Quantified In vivo by Ultrasound Relates to Amount of Gas Detected Post-mortem in Rabbits Decompressed from High Pressure.

Authors:  Yara Bernaldo de Quirós; Andreas Møllerløkken; Marianne B Havnes; Alf O Brubakk; Oscar González-Díaz; Antonio Fernández
Journal:  Front Physiol       Date:  2016-07-21       Impact factor: 4.566

4.  High-altitude decompression strain can be reduced by an early excursion to moderate altitude while breathing oxygen.

Authors:  Rickard Ånell; Mikael Grönkvist; Mikael Gennser; Ola Eiken
Journal:  Eur J Appl Physiol       Date:  2021-08-19       Impact factor: 3.078