Literature DB >> 24435796

Development and investigation of a mesh-electrode linear ion trap (ME-LIT) mass analyzer.

Liang Wang1, Fuxing Xu, Xinhua Dai, Xiang Fang, Chuan-Fan Ding.   

Abstract

A mesh-electrode linear ion trap (ME-LIT) mass analyzer was developed and its performance was primarily characterized. In conventional linear ion trap mass analyzers, the trapped ions are mass-selected and then ejected in a radial direction by a slot on a trap electrode. The presence of slots can strongly affect the electric field distribution in the ion trapping region and distort the mass analysis performance. To compensate for detrimental electric field effects, the slot is usually designed and fabricated to be as small as possible, and also has very high mechanical accuracy and symmetry. A ME-LIT with several mesh electrodes was built to compensate for the effects caused by slots. Each mesh electrode was fabricated from a plate electrode with a relatively large slot and the slot was covered with a conductive mesh. Our preliminary experimental results show that the ME-LIT could considerably diminish the detrimental electric field effects caused by slots, and increase the mass resolving power and ion detection efficiency. Even with 4-mm-wide slots, a mass resolution in excess of 600 was obtained using the ME-LIT. Mass resolution could be remarkably improved using mesh electrodes in ion traps with asymmetric electrodes. The stability diagram of the ME-LIT was mapped, and highly efficient tandem mass spectrometry was demonstrated. The ME-LIT was qualified as a LIT mass analyzer. The ME-LIT can improve the mass resolution and decrease the requirements of mechanical accuracy and symmetry of slots, so it shows potential for a wide range of practical uses.

Mesh:

Substances:

Year:  2014        PMID: 24435796     DOI: 10.1007/s13361-013-0803-x

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  26 in total

1.  Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications.

Authors:  John E P Syka; Jarrod A Marto; Dina L Bai; Stevan Horning; Michael W Senko; Jae C Schwartz; Beatrix Ueberheide; Benjamin Garcia; Scott Busby; Tara Muratore; Jeffrey Shabanowitz; Donald F Hunt
Journal:  J Proteome Res       Date:  2004 May-Jun       Impact factor: 4.466

Review 2.  Triple quadrupole linear ion trap mass spectrometer for the analysis of small molecules and macromolecules.

Authors:  Gérard Hopfgartner; Emmanuel Varesio; Viviane Tschäppät; Chantal Grivet; Emmanuel Bourgogne; Luc Alexis Leuthold
Journal:  J Mass Spectrom       Date:  2004-08       Impact factor: 1.982

Review 3.  Mass spectrometry as a diagnostic and a cancer biomarker discovery tool: opportunities and potential limitations.

Authors:  Eleftherios P Diamandis
Journal:  Mol Cell Proteomics       Date:  2004-02-28       Impact factor: 5.911

4.  Rectilinear ion trap mass spectrometer with atmospheric pressure interface and electrospray ionization source.

Authors:  Qingyu Song; Sameer Kothari; Michael A Senko; Jae C Schwartz; Jonathan W Amy; George C Stafford; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2006-02-01       Impact factor: 6.986

5.  Ion trap array mass analyzer: structure and performance.

Authors:  Xiaoxu Li; Gongyu Jiang; Chan Luo; Fuxing Xu; Yuanyuan Wang; Li Ding; Chuan-Fan Ding
Journal:  Anal Chem       Date:  2009-06-15       Impact factor: 6.986

6.  Handheld miniature ion trap mass spectrometers.

Authors:  Zheng Ouyang; Robert J Noll; R Graham Cooks
Journal:  Anal Chem       Date:  2009-04-01       Impact factor: 6.986

7.  Electrospray wings for molecular elephants (Nobel lecture).

Authors:  John B Fenn
Journal:  Angew Chem Int Ed Engl       Date:  2003-08-25       Impact factor: 15.336

8.  Design and characterization of a multisource hand-held tandem mass spectrometer.

Authors:  Liang Gao; Andy Sugiarto; Jason D Harper; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2008-08-29       Impact factor: 6.986

9.  Ion trap mass analysis at high pressure: an experimental characterization.

Authors:  Qingyu Song; Wei Xu; Scott A Smith; Liang Gao; William J Chappell; R Graham Cooks; Zheng Ouyang
Journal:  J Mass Spectrom       Date:  2010-01       Impact factor: 1.982

10.  Performance and geometry optimization of the ceramic-based rectilinear ion traps.

Authors:  Liang Wang; Fuxing Xu; Chuan-Fan Ding
Journal:  Rapid Commun Mass Spectrom       Date:  2012-09-15       Impact factor: 2.419

View more
  4 in total

Review 1.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

2.  Operation and Performance of a Mass-Selective Cryogenic Linear Ion Trap.

Authors:  Larry F Tesler; Adam P Cismesia; Matthew R Bell; Laura S Bailey; Nicolas C Polfer
Journal:  J Am Soc Mass Spectrom       Date:  2018-07-30       Impact factor: 3.109

3.  Infrared ion spectroscopy inside a mass-selective cryogenic 2D linear ion trap.

Authors:  Adam P Cismesia; Larry F Tesler; Matthew R Bell; Laura S Bailey; Nicolas C Polfer
Journal:  J Mass Spectrom       Date:  2017-11       Impact factor: 1.982

4.  A Linear Ion Trap with an Expanded Inscribed Diameter to Improve Optical Access for Fluorescence Spectroscopy.

Authors:  Vaishnavi Rajagopal; Chris Stokes; Alessandra Ferzoco
Journal:  J Am Soc Mass Spectrom       Date:  2017-08-18       Impact factor: 3.109