Literature DB >> 24433833

Dosimetric effect of Elekta Beam modulator micromultileaf in three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for prostate cancer.

Alessandra Carosi1, Gianluca Ingrosso2, Elisabetta Ponti2, Barbara Tolu2, Alessandra Murgia2, Daniela di Cristino2, Riccardo Santoni2.   

Abstract

The purpose of this study is to analyze the dosimetric effect of Elekta Beam Modulator in 3-dimensional conformal radiation therapy (3DCRT) and in intensity-modulated radiation therapy (IMRT) for localized prostate cancer. We compared treatment plans developed with 2 different Elekta multileaf collimators (MLC): Beam Modulator micro-MLC (mMLC) (4-mm leaf width at the isocenter) and standard MLC (10-mm leaf width at the isocenter). The comparison was performed for 15 patients with localized prostate cancer in 3DCRT and IMRT delivery; a total of 60 treatment plans were processed. The dose-volume histograms were used to provide the quantitative comparison between plans. In particular, we analyzed differences between rectum and bladder sparing in terms of a set of appropriate Vx (percentage of organ at risk [OAR] volume receiving the x dose) and differences between target conformity and coverage in terms of coverage factor and conformation number. Our analysis demonstrates that in 3DCRT there is an advantage in the use of Elekta Beam Modulator mMLC in terms of organ sparing; in particular, a significant decrease in rectal V60 and V50 (p = 0.001) and in bladder V70 and V65 (p = 0.007 and 0.002, respectively) was found. Moreover, a better target dose conformity was obtained (p = 0.002). IMRT plans comparison demonstrated no significant differences between the use of the 4 or 10-mm MLCs. Our analysis shows that in 3DCRT the use of the Elekta Beam Modulator mMLC gives a gain in target conformity and in OARs dose sparing whereas in IMRT plans there is no advantage.
Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3DCRT; Elekta Beam Modulator; IMRT; Prostate cancer

Mesh:

Year:  2014        PMID: 24433833     DOI: 10.1016/j.meddos.2013.12.006

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  3 in total

1.  Volumetric image-guided conformal radiotherapy for localized prostate cancer: Analysis of dosimetric and clinical factors affecting acute and late toxicity.

Authors:  Gianluca Ingrosso; Alessandra Carosi; Daniela di Cristino; Elisabetta Ponti; Andrea Lancia; Marta Bottero; Alessandro Cancelli; Alessandra Murgia; Irene Turturici; Riccardo Santoni
Journal:  Rep Pract Oncol Radiother       Date:  2018-08-13

2.  A systematic review and meta-analysis of radiotherapy planning studies comparing multi leaf collimator designs.

Authors:  Marco Luzzara; Luigi Santoro; Kevin Brown
Journal:  Phys Imaging Radiat Oncol       Date:  2018-03-23

3.  Dosimetric sensitivity of leaf width on volumetric modulated arc therapy plan quality: an objective approach.

Authors:  Ghulam Murtaza; Muhammad Shamshad; Munir Ahmed; Shahid Mehmood; Ehsan Ullah Khan
Journal:  Rep Pract Oncol Radiother       Date:  2022-03-22
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.