Literature DB >> 24431764

Magnet retained cheek plumper to enhance denture esthetics: case reports.

V Kamakshi1, Gouri V Anehosur1, Ramesh K Nadiger1.   

Abstract

Handicap due to the loss of teeth in patients can be severe due to the impairment of masticatory function and facial disfigurement leading to negative psychological impact on the individual. To combat this, apart from the regular measures of positioning the teeth to obtain lip support, excellent denture esthetics can be achieved by providing additional support to the slumped tissues. This clinical report highlights a technique to provide support for sunken cheeks using detachable acrylic cheek plumpers, retained using iron-neodymium close-field magnets. The use of these magnets is a modification from the conventional technique of supporting the slumped tissues.

Entities:  

Keywords:  Cheek plumper; Closed field magnets; Denture esthetics; Elderly; Psychological stress; Sunken cheeks

Year:  2012        PMID: 24431764      PMCID: PMC3732701          DOI: 10.1007/s13191-012-0200-3

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  6 in total

Review 1.  Magnets in prosthetic dentistry.

Authors:  M A Riley; A D Walmsley; I R Harris
Journal:  J Prosthet Dent       Date:  2001-08       Impact factor: 3.426

2.  Magnetic strength and corrosion of rare earth magnets.

Authors:  Khalid A Ahmad; James L Drummond; Thomas Graber; Ellen BeGole
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-09       Impact factor: 2.650

Review 3.  Prosthodontic considerations for the older patient.

Authors:  S R Zwetchkenbaum; K Shay
Journal:  Dent Clin North Am       Date:  1997-10

4.  Interference of neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators: an in vitro study.

Authors:  Salome Ryf; Thomas Wolber; Firat Duru; Roger Luechinger
Journal:  Technol Health Care       Date:  2008       Impact factor: 1.285

5.  The safety of dental mini-magnets in patients with permanent cardiac pacemakers.

Authors:  H Hiller; N Weissberg; G Horowitz; M Ilan
Journal:  J Prosthet Dent       Date:  1995-10       Impact factor: 3.426

6.  Prosthetic support for unilateral facial paralysis.

Authors:  S J Larsen; J F Carter; H A Abrahamian
Journal:  J Prosthet Dent       Date:  1976-02       Impact factor: 3.426

  6 in total
  2 in total

1.  Enhancing Facial Esthetics in a Complete Denture Patient Having Sunken Cheeks With a Hollow Fixed Cheek Plumper: A Case Report.

Authors:  Shreya Colvenkar; Suman Pathipaka; Devarakonda Siva Santosh Babu; Kasukurthi Vijay Kumar; Rathod Prakash
Journal:  Cureus       Date:  2022-07-31

2.  An Innovative Technique Using a Stainless Steel Double Die Pin Retained Cheek Plumper in Complete Denture Esthetics: A Case Report.

Authors:  Sriharsha Pudi; Shanthipriya Kota; Karthik K V G Ch; Sainath Reddy Kaladi; Rajasekhar Reddy Gade
Journal:  Cureus       Date:  2019-11-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.