Literature DB >> 24431732

Force Finishing and Centering to Balance a Removable Complete Denture Prosthesis Using the T-Scan III Computerized Occlusal Analysis System.

Robert B Kerstein1, Prafulla Thumati2, S Padmaja3.   

Abstract

Obtaining bilateral balance of removable complete denture prostheses is the occlusal goal of the restorative dentist or prosthodontist. Despite our best clinical efforts, and the using of advanced mechanical devices like semi-adjustable articulators and face bow transfer mounting of dental casts, it is a struggle to provide accurate occlusal force balance. Some of the advocated reasons for the clinical difficulty of obtaining reliable occlusal balance are that stone casts lack soft tissue resiliency, and articulators only approximate human occlusal functional movements. However, modern technology offers clinicians a digital answer to this clinical force balance problem. It is known as computerized occlusal analysis. The T-Scan III system can be employed with complete removable denture prostheses to perform computer-guided occlusal force-finishing corrective adjustments that measurably improve the installed prosthetic occlusal balance.

Entities:  

Keywords:  Force centering; Force-finishing; Measurable occlusal balance; T-Scan III computerized occlusal analysis system

Year:  2013        PMID: 24431732      PMCID: PMC3732729          DOI: 10.1007/s13191-013-0287-1

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  3 in total

1.  Distribution of occlusal contacts in maximum intercuspation.

Authors:  W L Maness; R Podoloff
Journal:  J Prosthet Dent       Date:  1989-08       Impact factor: 3.426

2.  Quantitative analysis of occlusal balance in intercuspal position using the T-Scan system.

Authors:  M Mizui; F Nabeshima; J Tosa; M Tanaka; T Kawazoe
Journal:  Int J Prosthodont       Date:  1994 Jan-Feb       Impact factor: 1.681

Review 3.  A comparison of traditional occlusal equilibration and immediate complete anterior guidance development.

Authors:  R B Kerstein
Journal:  Cranio       Date:  1993-04       Impact factor: 2.020

  3 in total
  4 in total

1.  Occlusion and Disocclusion Time Changes in Single Unit Crowns Designed by Functional Generated Path Technique: A Randomised Clinical Trial.

Authors:  Ping-Ting Lin; Yang Jiao; San-Jun Zhao; Fu Wang; Ling Li; Fan Yu; Min Tian; Hao-Han Yu; Ji-Hua Chen
Journal:  Sci Rep       Date:  2017-03-24       Impact factor: 4.379

2.  Evaluation of the Accuracy of a System to Align Occlusal Dynamic Data on 3D Digital Casts.

Authors:  Iñigo de Prado; Mikel Iturrate; Rikardo Minguez; Eneko Solaberrieta
Journal:  Biomed Res Int       Date:  2018-06-06       Impact factor: 3.411

3.  Jaw relationship assessment for removable complete dentures using the t-scan computerised system - a case report.

Authors:  Szidónia Renáta Akácsos; Melinda Kis; Melinda Székely; Sorin Popşor; Kinga Dörner
Journal:  Med Pharm Rep       Date:  2019-12-15

4.  Digital occlusal analysis of pre and post single posterior implant restoration delivery: A pilot study.

Authors:  Ting Zhou; Jirapa Wongpairojpanich; Maytha Sareethammanuwat; Charukrit Lilakhunakon; Borvornwut Buranawat
Journal:  PLoS One       Date:  2021-07-02       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.