Literature DB >> 24427798

Influence of axial length and corneal power on the astigmatic power of toric intraocular lenses.

Giacomo Savini, Kenneth J Hoffer, Michele Carbonelli, Pietro Ducoli, Piero Barboni.   

Abstract

PURPOSE: To assess the influence of the anterior chamber depth (ACD), predicted by corneal power (keratometry [K]), and axial length (AL) on the astigmatic power of toric intraocular lenses (IOLs).
SETTING: Private practice, Bologna, Italy.
DESIGN: Noninterventional theoretical study.
METHODS: Meridional analysis (based on the Hoffer Q formula) was applied to an eye model with K ranging from 38.0 to 48.0 diopters and AL ranging from 20 to 30 mm. For each diopter (D) of K and each millimeter of AL, the ratio between the toricity at the IOL plane and the toricity at the corneal plane was computed. Several simulations with the Acrysof toric IOL were performed.
RESULTS: The ratio between toricity at the IOL plane and toricity at the corneal plane depended on the predicted ACD. The highest value (1.86) was found with the steepest K (48.0 D) and longest AL (30.0 mm) and the lowest value (1.29), with the flattest K (38.0 D) and shortest AL (20.0 mm). When applied to the toric IOL, the results suggest that a low ratio (≤1.41) led to overcorrection of astigmatism relative to the value reported by the manufacturer's online calculator. In contrast, a high ratio (>1.60) led to undercorrection of the astigmatism.
CONCLUSION: The ACD influenced the ratio between the cylinder power in the IOL plane and the cylinder power in the corneal plane and should be accounted for when selecting a toric IOL in an eye whose K and AL are far from the average values.

Entities:  

Mesh:

Year:  2013        PMID: 24427798     DOI: 10.1016/j.jcrs.2013.04.047

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  Accuracy of corneal astigmatism correction with two Barrett Toric calculation methods.

Authors:  Jun Yang; Hong Zhang; Xiao-Tong Yang; Fang Tian; Shao-Zhen Zhao
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

2.  Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position.

Authors:  Youngsub Eom; Dongok Ryu; Dae Wook Kim; Seul Ki Yang; Jong Suk Song; Sug-Whan Kim; Hyo Myung Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-08-19       Impact factor: 3.117

Review 3.  Optimizing outcomes with toric intraocular lenses.

Authors:  Manpreet Kaur; Farin Shaikh; Ruchita Falera; Jeewan S Titiyal
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

4.  The efficiency of aspheric intraocular lens according to biometric measurements.

Authors:  Woong-Joo Whang; Junjie Piao; Young-Sik Yoo; Choun-Ki Joo; Geunyoung Yoon
Journal:  PLoS One       Date:  2017-10-16       Impact factor: 3.240

5.  Use of the toric intraocular lens for keratoconus treatment.

Authors:  Jasmin Zvornicanin; Emir Cabric; Vahid Jusufovic; Zlatko Musanovic; Edita Zvornicanin
Journal:  Acta Inform Med       Date:  2014-04

6.  A Direct Method for Determining Toricity Ratios of Toric Intraocular Lens Calculators.

Authors:  Lauren G Gabra; Samir I Sayegh
Journal:  Sci Rep       Date:  2018-03-15       Impact factor: 4.379

7.  Anterior Chamber Angle and Volume Do Not Change after Myopic Laser-Assisted In Situ Keratomileusis in Young Patients.

Authors:  Ertuğrul Tan Yassa; Cihan Ünlü
Journal:  J Ophthalmol       Date:  2018-12-10       Impact factor: 1.909

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.