Literature DB >> 24427464

Successful resuscitation of cardiac arrest caused by CO2 embolism with intra-aortic injection of epinephrine during off-pump coronary bypass surgery -a case report-.

Choon Soo Lee1, Yeo Sam Yoon1, Jae-Kwang Shim2, Hyun Kyoung Lim1.   

Abstract

Although compressed gas (CO2) blowers have been used safely to aid accurate grafting during off-pump coronary bypass surgery, hemodynamic collapse due to gas embolism into the right coronary artery may occur. Supportive measures to facilitate gas clearance by increasing the coronary perfusion pressure have been reported to be successful in restoring hemodynamic stability. However, right ventricular dysfunction and atrioventricular nodal ischemia may hinder effective systemic delivery of the vasoactive medications, even when performing resuscitative measures such as direct cardiac massage. We herein report a case of cardiac arrest that was caused by a right coronary gas embolism and that could not be restored by cardiac resuscitation. When supportive measures fail, direct aortic injection of epinephrine to increase the coronary perfusion pressure can be attempted before initiating cardiopulmonary bypass, and this approach may be life-saving in situations that limit systemic drug delivery from the venous side despite the performance of direct cardiac massage.

Entities:  

Keywords:  Ascending aorta; Cardiac arrest; Epinephrine; Gas embolism; Off-pump coronary artery bypass

Year:  2013        PMID: 24427464      PMCID: PMC3888851          DOI: 10.4097/kjae.2013.65.6.562

Source DB:  PubMed          Journal:  Korean J Anesthesiol        ISSN: 2005-6419


  6 in total

1.  A new proposal of CPR based on coronary perfusion pressure.

Authors:  J Eldor
Journal:  Resuscitation       Date:  1992-02       Impact factor: 5.262

2.  Aborted off-pump coronary artery bypass patients have much worse outcomes than on-pump or successful off-pump patients.

Authors:  Ruyun Jin; Loren F Hiratzka; Gary L Grunkemeier; Albert Krause; U Scott Page
Journal:  Circulation       Date:  2005-08-30       Impact factor: 29.690

3.  Gaseous emboli during off-pump surgery with T-graft technique, two different mechanisms.

Authors:  Akmal M A Badreldin; Alexander A Albert; Mohamed M Ismail; Matthias Heldwein; Fabian Doerr; Torsten Bossert; Artur Lichtenberg; Khosro Hekmat
Journal:  Interact Cardiovasc Thorac Surg       Date:  2010-02-12

4.  Aortic arch versus central venous epinephrine during CPR.

Authors:  J E Manning; C A Murphy; D N Batson; S G Perretta; R A Mueller; E A Norfleet
Journal:  Ann Emerg Med       Date:  1993-04       Impact factor: 5.721

5.  Intracardiac injection.

Authors:  P R Martens
Journal:  Resuscitation       Date:  1994-03       Impact factor: 5.262

6.  Carbon dioxide embolism induced right coronary artery ischaemia during off-pump obtuse marginalis artery grafting.

Authors:  Jae Kwang Shim; Yong Seon Choi; Kyung Jong Yoo; Young Lan Kwak
Journal:  Eur J Cardiothorac Surg       Date:  2009-07-07       Impact factor: 4.191

  6 in total