Literature DB >> 24426180

Numerical Modeling of Indoor Environment with a Ceiling Fan and an Upper-Room Ultraviolet Germicidal Irradiation System.

Shengwei Zhu1, Jelena Srebric2, Stephen N Rudnick3, Richard L Vincent4, Edward A Nardell5.   

Abstract

This study proposes a numerical modeling method for the indoor environment with ceiling fans and upper-room ultraviolet germicidal irradiation (UR-UVGI) fixtures. The numerical modeling deployed steady-state Computational Fluid Dynamics (CFD) with a rotating reference frame to simulate the rotation of fan blades. CFD was validated with experimental data of velocity field and fraction of microorganism remaining at the exhaust diffuser. The fraction of microorganism remaining represented the ratio of the concentration of airborne microorganisms measured with UVGI turned on to the one measured with UVGI turned off. According to the validation results, the CFD model correctly reproduced the air movement induced by the rotation of ceiling fan. When the ambient ventilation rate was 2 ACH (air changes per hour) or 6 ACH, the CFD model accurately predicted the average vertical speeds in the section 2.44 m above the floor with the errors less than 10%, regardless of the ceiling fan's rotational direction or speed. In addition, the simulation results showed that the fraction of microorganism remaining increased with the ambient air exchange rate when the fan blew air downward with a rotational speed as high as 235 rpm, which corresponded with the experimental results. Furthermore, the simulation results accurately predicted the fraction of microorganism remaining when the ambient air exchange rate was 2 ACH. We conclude that this novel numerical model can reproduce the effects of ceiling fans and UR-UVGI fixtures on indoor environment, and should aid in the investigation of the impact of ceiling fans on UR-UVGI disinfection efficacy.

Entities:  

Keywords:  Airborne infection control; Ceiling fan; Computational fluid dynamics; Fraction of microorganism remaining; Upper-room ultraviolet germicidal irradiation

Year:  2014        PMID: 24426180      PMCID: PMC3888502          DOI: 10.1016/j.buildenv.2013.10.019

Source DB:  PubMed          Journal:  Build Environ        ISSN: 0360-1323            Impact factor:   6.456


  9 in total

1.  Fundamental factors affecting upper-room ultraviolet germicidal irradiation - part I. Experimental.

Authors:  Melvin First; Stephen N Rudnick; Kevin F Banahan; Richard L Vincent; Phillip W Brickner
Journal:  J Occup Environ Hyg       Date:  2007-05       Impact factor: 2.155

2.  Fundamental factors affecting upper-room ultraviolet germicidal irradiation - part II. Predicting effectiveness.

Authors:  Stephen N Rudnick; Melvin W First
Journal:  J Occup Environ Hyg       Date:  2007-05       Impact factor: 2.155

3.  Effect of relative humidity on the inactivation of airborne Serratia marcescens by ultraviolet radiation.

Authors:  R L Riley; J E Kaufman
Journal:  Appl Microbiol       Date:  1972-06

4.  Room air disinfection by ultraviolet irradiation of upper air. Air mixing and germicidal effectiveness.

Authors:  R L Riley; S Permutt
Journal:  Arch Environ Health       Date:  1971-02

5.  Room air disinfection by ultraviolet irradiation of upper air. Further analysis of convective air exchange.

Authors:  R L Riley; S Permutt; J E Kaufman
Journal:  Arch Environ Health       Date:  1971-07

6.  A multi-institutional outbreak of highly drug-resistant tuberculosis: epidemiology and clinical outcomes.

Authors:  T R Frieden; L F Sherman; K L Maw; P I Fujiwara; J T Crawford; B Nivin; V Sharp; D Hewlett; K Brudney; D Alland; B N Kreisworth
Journal:  JAMA       Date:  1996-10-16       Impact factor: 56.272

7.  Upper-room ultraviolet light and negative air ionization to prevent tuberculosis transmission.

Authors:  A Roderick Escombe; David A J Moore; Robert H Gilman; Marcos Navincopa; Eduardo Ticona; Bailey Mitchell; Catherine Noakes; Carlos Martínez; Patricia Sheen; Rocio Ramirez; Willi Quino; Armando Gonzalez; Jon S Friedland; Carlton A Evans
Journal:  PLoS Med       Date:  2009-03-17       Impact factor: 11.069

8.  Numerical investigation of upper-room UVGI disinfection efficacy in an environmental chamber with a ceiling fan.

Authors:  Shengwei Zhu; Jelena Srebric; Stephen N Rudnick; Richard L Vincent; Edward A Nardell
Journal:  Photochem Photobiol       Date:  2013-01-30       Impact factor: 3.421

9.  An outbreak of multi-drug-resistant tuberculosis in a London teaching hospital.

Authors:  A S Breathnach; A de Ruiter; G M Holdsworth; N T Bateman; D G O'Sullivan; P J Rees; D Snashall; H J Milburn; B S Peters; J Watson; F A Drobniewski; G L French
Journal:  J Hosp Infect       Date:  1998-06       Impact factor: 3.926

  9 in total
  6 in total

Review 1.  Transmission and Institutional Infection Control of Tuberculosis.

Authors:  Edward A Nardell
Journal:  Cold Spring Harb Perspect Med       Date:  2015-08-20       Impact factor: 6.915

2.  A review of facilities management interventions to mitigate respiratory infections in existing buildings.

Authors:  Yan Zhang; Felix Kin Peng Hui; Colin Duffield; Ali Mohammed Saeed
Journal:  Build Environ       Date:  2022-06-28       Impact factor: 7.093

3.  Institutional Tuberculosis Transmission. Controlled Trial of Upper Room Ultraviolet Air Disinfection: A Basis for New Dosing Guidelines.

Authors:  Matsie Mphaphlele; Ashwin S Dharmadhikari; Paul A Jensen; Stephen N Rudnick; Tobias H van Reenen; Marcello A Pagano; Wilhelm Leuschner; Tim A Sears; Sonya P Milonova; Martie van der Walt; Anton C Stoltz; Karin Weyer; Edward A Nardell
Journal:  Am J Respir Crit Care Med       Date:  2015-08-15       Impact factor: 21.405

4.  Lagrangian modeling of inactivation of airborne microorganisms by in-duct ultraviolet lamps.

Authors:  Yi Yang; Huihui Zhang; Alvin Ck Lai
Journal:  Build Environ       Date:  2020-11-21       Impact factor: 6.456

5.  Ceiling impact on air disinfection performance of Upper-Room Germicidal Ultraviolet (UR-GUV).

Authors:  Shengwei Zhu; Tong Lin; Lingzhe Wang; Edward A Nardell; Richard L Vincent; Jelena Srebric
Journal:  Build Environ       Date:  2022-08-31       Impact factor: 7.093

6.  Influence of ceiling fan's speed and direction on efficacy of upperroom, ultraviolet germicidal irradiation: Experimental.

Authors:  S N Rudnick; J J McDevitt; G M Hunt; M T Stawnychy; R L Vincent; P W Brickner