Literature DB >> 24424660

Type A acute aortic dissection: why does the false channel remain patent after surgery?

Fabrice Bing1, Mathieu Rodière, Thomas Martinelli, Valérie Monnin-Bares, Olivier Chavanon, Vincent Bach, Jean-Philippe Baguet, Gilbert R Ferretti, Frédéric Thony.   

Abstract

PURPOSE: To understand why the false channel (FC) remains patent after surgery of type A acute aortic dissection (TAAAD).
MATERIALS AND METHODS: Postoperative contrast-enhanced computed tomography scans of 129 patients operated for TAAAD were analyzed, and a color-Doppler ultrasound examination (CDUS) of the supra-aortic vessels (SAVs) was performed in 12 patients.
RESULTS: The FC remained patent in 107 (82.9%) patients. The entry site was situated near the distal anastomosis in 43 (40.2%) patients and far from it in 44 (41.1%) patients. In 10 (9.35%) patients, an entry site was observed only in the SAVs. In 10 (9.35%) patients, no entry site was seen. Of the 12 patients explored with CDUS, a retrograde filling of the FC was observed in 11 patients.
CONCLUSION: The frequent postoperative circulating aortic FC can be explained by the persistence of the primary entry tear, the presence of iatrogenic tears, and/or a retrograde filling in the SAVs.

Entities:  

Keywords:  CT scanner; Doppler ultrasound; aortic dissection; false channel; intimal tear

Mesh:

Year:  2014        PMID: 24424660     DOI: 10.1177/1538574413518611

Source DB:  PubMed          Journal:  Vasc Endovascular Surg        ISSN: 1538-5744            Impact factor:   1.089


  5 in total

1.  Predictors of patent false lumen of the aortic arch after hemiarch replacement.

Authors:  Gaku Uchino; Takeki Ohashi; Hiroshi Iida; Masao Tadakoshi; Souichirou Kageyama; Masato Furui; Noriko Kodani
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-08-02

2.  Role of proximal and distal tear size ratio in hemodynamic change of acute type A aortic dissection.

Authors:  Xiaonan Li; Huanyu Qiao; Yue Shi; Jinrong Xue; Tao Bai; Yongmin Liu; Lizhong Sun
Journal:  J Thorac Dis       Date:  2020-06       Impact factor: 2.895

3.  Repair of Acute Type-A Aortic Dissection in the Present Era: Outcomes and Controversies.

Authors:  Ellie Moeller; Marcos Nores; Sotiris C Stamou
Journal:  Aorta (Stamford)       Date:  2020-04-09

4.  Commentary: Management of acute type A aortic dissection with patent false lumen: A rivalry between surgical data and philosophy.

Authors:  Irbaz Hameed; Arnar Geirsson; Roland Assi
Journal:  JTCVS Tech       Date:  2021-06-23

5.  Surgical outcomes associated with sleep apnea syndrome in Stanford A aortic dissection patients.

Authors:  Zeng-Rong Luo; Ling-Li Yu; Liang-Wan Chen
Journal:  BMC Cardiovasc Disord       Date:  2022-07-24       Impact factor: 2.174

  5 in total